V
Download the .JSON, open Node Red from VRM (Venus OS Large) , In Node Red click the top three lines on the right, click import, select the.JSON you downloaded then when it’s showing on your flow, click big red Deploy button. Double click on the nodes to find out more info on them. You can click on the Inject nodes (Open / Close) and should hear your Cerbo relay clicking
V
Thanks this gives me a good starting point. I’ll try the ai option first that somone kindly made for me. And see how that goes. But knowing how to set nodes manually is for me just as important so thanks again.
V
Wow this looks promising, thanks for going round that effort. It never dawned on me to ask an ai for help, yet i use chat gpt all the time. Just one question, once I download this file, how do I install it into my node red screen?
V
So if I sold you a 200-watt panel and the best you could get out of it was 10 watts you would be good with that? Why even put a rating on the panel then. Just sell panels by the size and tell your customers “Good Luck” You’re right, I don’t believe that is how it should be. We will be going to space and we need things that are going to function the way they are intended. Actually now that I think about it you sound like one of the people that manufactures solar panels and does not want to be…
V
On the screen, go to the Settings > VRM. What is the Connection Status? When did is the Last Contact? This might tell us when the problem started. Do you know what changed at that time? What was the old version of firmware on the Cerbo before you updated it to 3.81? Did you reboot the Cerbo? Did you try reverting to the old firmware? 3.85 is current. Changing firmware is not always a good idea. Check VRM for logs: If you use the laptop to connect to VRM, are there messages in the logs? Check…
V
Hola Tengo dos Multiplus 5000/48/70 funcionando en paralelo con cerbo y un grupo electrógeno de 7kva, tengo picos de potencia al arrancar motores de poco más de 10kw y un consumo de trabajo de unos 5kw, cuando arranca el grupo electrógeno, la mayoría de las veces se vuelve loco y se acelera a tope, yo lo tengo limitado en intensidad o en VE CONFIGURE o en la propia pantalla GX, o lo paro el grupo o termina cortando por sobre potencia, además tenemos dos iguales, uno de reserva y con los dos…
V
Je hebt gelijk, ik heb het zojuist ook gelezen op hun site!
V
Ben je tevreden over de V3 BMS en de actieve balancer? Ik weet uit betrouwbare bron dat sommige groothandels specifiek de Seplos V3 BMS gebruiken vanwege zijn betrouwbaarheid. Deze wordt dan gecombineerd met een simpele actieve 2A balancer (JK-B2A16S) van Jk. De JK actieve BMS wordt bewust niet gebruikt vanwege een hoger uitval percentage. De actieve Seplos BMS die je gebruikt durfde men nog niet aan omdat er nog geen betrouwbaarheid gegevens van zijn. Welke gebruik je precies 200A/300A?
V
Ik heb inderdaad een Renault 5 etech met 52 kwh accu die dat kan. Bi directioneel kan een grote plus zijn. Ik hoop dat de prijs meevalt.
V
Thanks for the update. Did they give you a rough idea on the timescales?
V
In een superpack ng zit verwarming en met een smartshunt een prima verbinding met een Cerbo.
V
So from following up with Victron themselves it appears that the issue is as follows. The first submission required corrections to the test certificate. These were actioned and the certificate was resubmitted. ENA rejected it as non compliant because those were incorporated via an addendum rather than in the body of the certificate itself. So currently it would appear that the test house need to produce a new certificate with the relevant corrections in line and then submit that. It seems like…
V
Gobel will supply the tinned copper flexible busbars normally like the ones in pau1phi11ips picture, but small things like that are always good to check before ordering, they will also supply other variants if you ask and they can find them, but I’d stick to the tinned copper flexible. I bought some Gotion 340Ah cells from Gobel in 2023, they couldn’t supply the flexible bars as standard at the time as the cells were a larger size than standard LF280K, so they sent solid tinned busbars, which…
V
not imediatly, NS version will stay for a while
V
Seplos V3 BMS with an JK BMS Active Balancer
V
Hola @YonneSolaire Creo que se está sobreentendiendo que quieres mezclar en CC las dos baterías a través de un embarrado o algo similar. ¿Tu pregunta consiste en sólo saber si el cerbo puede gestionar los dos bms de las dos baterías por separado? Pero, las baterías, ¿serían cargadas por separado sin mezclar voltajes? La verdad es que es algo confuso sin saber más del sistema o lo que se quiere conseguir. Saludos,
V
Zo te zien gebruik je een Seplos active balancer (de print boven).
V
Will the old version of the EVCS continue to be sold alongside the new version once it becomes available, or will the old version be withdrawn from sale immediately?
V
Ik wil de originele EVE mb31 hsev grade a bestellen bij Gobel via het filiaal in de EU. Daar zijn de single stud ruim op voorraad. Ik weet niet welke Busbar er bij geleverd wordt, ik ging er vanuit dat het aluminium zou zijn. Maar ik heb inderdaad eerder gehoord van oxidatie op de busbars, volgens mij was het Andy van the Off-Grid Garage (YT).
V
What is the link beetwen this and my 2 batteries 4,8 and 16 kWh ?
V
I run parallel mp2’s using a wide variety of led lighting, from 50W flood lights, smart lights (shelly, philips, sonoff) to fixed dimmable and non-dimmable fittings (osram/philips). Zero flickering apart from dimmers at very low power and grid or no grid makes no difference. The dimmer/fitting pairing matters. The only time something starts to flicker is when the driver is on its way out.
V
Ik kan me nog voorstellen dat een klassieke voeding met trafo, gelijkrichters en afvlakcondensatoren wel werkt. Of een 24v startaccu die ondertussen opgeladen wordt.
V
Ernst6a: Hattest du den Regler Passwirt geschützt? Ja, Hatte ich, das was mir keine ruhe lässt ist auch die Uhrzeit des Ausfall, das schraubt ja wirklich keiner mehr umher.
V
Werner geeft aan dat het smartsolar is. De smartsolar heeft tegenwoordig een eigen pincode. Met de pukcode die op het apparaat staat kun je altijd de pincode wijzigen, dat kan niet zo moeilijk zijn.
V
nicolas: Concernant la limitation de puissance Enphase, j’ai bien regardé ta documentation, mais mes essais ne sont malheureusement pas concluants. As-tu bien demandé l’activation de la fonctionnalité ? As-tu bien communiqué l’adresse IP de ton GX (Venus OS sur Raspberry Pi) ? On a tous galéré en mai et juin suite au changement de serveur Modbus TCP sur la passerelle Enphase (plus d’infos). C’est peut-être lié. J’avais moi-même eu un retour “Slave Device Busy” qui avait été résolu par le…
V
I have two Orion XS-50. Sometimes, I am able to start the emergency charging feature on both units, sometimes not. In this case, when I am trying to start the 2nd unit, it’s too late. The 2nd unit already started to charge back the lithium/house battery, creating a loop. I am using “Automatic engine shutdown detection” instead of the Remote input to trigger charging the lithium/house battery. I might have to change the voltages settings to trigger the automatic detection or, wire the remote…
V
Het flashen met victron connect heeft gewerkt evenals de eerste setup. Dankjulliewel voor het delen van de links. Nadat ik deze stappen heb gemaakt met victron connect lijkt nu ook VE CONFIGURE te werken. Ik moet nog even wat documentatie gaan lezen voor het invullen van de ESS assistant data maar ben in elk geval al iets opgeschoten
V
Callmebackdraft: first of all i started with VE Flash in order to update the firmware however, while the system is able to auto detect the comport it subsequently doesn’t want to connect to the multiplus. You update these days with Victron connect. It makes it easy
V
Check the rj45 plug on the rs 6000, if the plug is inserted you can not pull it out because the clip…but, On my rs 6000 the clip didn’t hold the rj45 in the socket sometimes causing communication errors, I had this problem for several months before I was aware of the faulty rj45 socket inside the RS6000, new cables didn’t help, now a simple matchstick keeps the plug in the socket, and never had a communication error again.. I do believe it was a error with the 3p75ct meter.
V
Hallo, ein ganz anderer Ansatz: Ist es ein Smartregler? Hattest du den Regler Passwirt geschützt? Mir hatte einmal ein netter Mitbürger meine ungeschüzten Regler ausgeschaltet. Ich habe lange gebraucht, um es wieder in gang zu setzen.