Fronius inverters not detected by Cerbo GX; Datcom Status shows Error

Hello everyone, I’m trying to connect four Fronius inverters at an installation in Lochem to a Victron Cerbo GX so that their data can be monitored. The Cerbo GX does not detect the inverters when I run a scan. I connected a laptop directly to the Datamanager and accessed 169.254.0.180. The web interface opens, but it requires a username and password. The customer no longer has these credentials. I also contacted the company that installed the system, but they could not help with the login…

MPPT RS 450/100 and partial shading of a string

Can you post a photo of the full array layout please (All strings)? Can you post a string wiring diagram (for the whole array) and the model of the panels? Have you tried swapping strings 1 and two on the MPPTs? To eliminate the fact that the MPPT may be the issue rather than some issue with the modules? If string 2 performs badly on MPPT 1, then MPPT 2 may be the culprit. If the behaviour is the same, it may be that there is an issue with the strings. Jona

Pylontech SOC drift below SOC min and ESS in external control oscillates in pumping network

Bonjour, Merci pour vos retours. Les batteries sont câblées individuellement. Et de toute façon le problème se pose à très basse puissance de charge/décharge. Je suis en TT côté AC (raccordé au réseau) et TBTS côté batterie, mais je ne consomme rien de ce côté-là (sauf le cerbo évidemment). Les batteries sont chargées uniquement par le chargeur du quattro à partir du surplus AC. Pas de MPPT. Les screenshots montrent un DC très stable qui dérive lentement au-delà du seuil max DC et en-dessous du…

EVCS + Shelly + Nodered-EVCS Manual mode blocked by minimum SOC when supplied from the grid with Mul

Squall: This is a forum that victron promotes to engage customers, so lets engage Victron guys also! To set the correct expectation, the community is not an official support site or the place to “ask Victron”. When you choose to modify a system it may not work as expected, or when software changes are made, it may not keep working as expected. There has never been any support for modified solutions like this, nor nodered flows, nor unsupported energy meters - this last piece is expressly stated…

EVCS + Shelly + Nodered-EVCS Manual mode blocked by minimum SOC when supplied from the grid with Mul

You have created a fundamental problem: The EVCS is physically connected to the grid. The MultiPlus-II is in Inverter Only. The GX receives an artificially generated grid-meter value. The EVCS uses information from the GX to determine the operating conditions and charging permissions. So if it is set to only discharge to 40% that is where it will stop. The system is therefore being presented with an inconsistent picture of its electrical state. It is off-grid… What did you tell the ev charger…

EVCS + Shelly + Nodered-EVCS Manual mode blocked by minimum SOC when supplied from the grid with Mul

Refer to the manual for ESS and loads before the inverter. victronenergy.com.au 3.1. Grid arrangement - 3. System design Designing the system is a matter of making a few decisions in sequence. Each decision narrows the design, and together they determine the topology and the components needed. This chapter takes those decisions in order: how the installation connects... A grid meter is a requirement in this configuration. If you want official Victron support, surely the starting point should be…

Cerbo GX stuck in Demo Mode and Danish language after power outage/overload recovery

I’m experiencing a strange issue on a remote off-grid installation using: Cerbo GX MK2 GX Touch 50 MultiPlus-II 48/5000/70-50 SmartSolar MPPT 250/70 Lithium battery bank Last week the system experienced a MultiPlus overload condition (red overload LED). The site was recovered by: Turning OFF AC load breaker. Turning OFF MultiPlus inverter. Turning OFF DC breaker. Waiting a few minutes. Turning ON DC breaker. Turning ON MultiPlus. Reconnecting AC loads. After the restart, the power system is…

MPPT won't push 24v after night if battery goes to zero when sun comes back out

Daniel: Shouldn’t DVCC disabled on the cerbo make the MPPT work in standalone? If the mppt was reset afterwards. Check with Victron connect and Bluetooth and yes it is possible to monitor it like that. Have you updated it and programmed it? Daniel: can have the battery protect “switch” the HOT off going to the DCDC device when voltage is under a certain point Yes. Daniel: On a lifepo4 24V what would be the voltage to set it to? 24V even maybe? Thats around 10%? Possibly. It might be too low…

DC bus bar sizing

Nkarpiak: Parallel vs spilt phase The differences here would be how you use them and voltages/supply used or needed. The following article should help you choose shop.pkys.com Setting up Parallel and three phase systems using the MultiPlus and Quattro...

Cerbo gx MK2 et jkbms avec waveshare

Hi Laurent — your instinct is right that the connector is the tricky part, but there is a trap here: JK uses the same white 4-pin connector for both buses, in two mirrored versions, and which one you have depends on the exact model and hardware revision. The V19H board is new enough that you should not rely on the older B2A tables alone. The two published variants for this 4-pin header are: - Common variant: pin 1 = CAN_L, pin 2 = CAN_H, pin 3 = RS485_A, pin 4 = RS485_B. This is the table that…

Expanding a 12.8V LiFePO4 Solar System Using a DC-DC Charger

I’m setting up something similar for a small off-grid cabin near Phoenix, so the 10A BMS limit caught my attention too. My plan is to swap the 54Ah for a bigger single battery rather than chain a DC-DC charger, since that seems simpler and avoids conversion losses. I looked at an ECO-WORTHY 12V 280Ah LiFePO4 Battery Review while comparing options, but I’m unsure whether 280Ah plus your daily 1,080 Wh load really covers three days of autonomy. My main worry is whether one inverter handles the…

DC bus bar sizing

This is an off grid system located in New Hampshire USA. I have (2) 12/3000/120amp wired in split phase going to a 100amp auto transformer. Then from the auto transformer it goes into a 110/220v 100amp breaker box that feeds the whole house. On an average day my Ac load is around 200-300 watts (unless I use the microwave,dishwasher, etc.). The Instant water heater, clothes dryer, range are all propane. The largest load is a 3/4hp 220v 8amp Well pump that turns on maybe twice a day for a couple…

MPPT won't push 24v after night if battery goes to zero when sun comes back out

On the battery protect product.. Is it like a switch that monitors the battery voltage and just kills power to something? Most of my draw is going to a DCDC convertor that powers a network switch. I can have the battery protect “switch” the HOT off going to the DCDC device when voltage is under a certain point? Which would let my cerbo make it to the morning and when the sun comes back out and it charges again it would turn it back on? On a lifepo4 24V what would be the voltage to set it to?…

MPPT won't push 24v after night if battery goes to zero when sun comes back out

With DVCC disabled this issue still happens. It’s the strangest thing. Shouldn’t DVCC disabled on the cerbo make the MPPT work in standalone? Yes I know something should be in place not to let battery go to zero but… Battery goes to zero overnight. BMS turns off battery. Everything dies inside my box. Sun comes out in morning - full sun. MPPT comes sort of on. Lights come on it. volt meter across PV shows full array voltage. voltage across battery on mppt shows like 1.5v The cerbo is completely…

Nieuwe 3.80 virtuele EVCS node, hoe vul ik de KWH waarde in het tegeltje?

message de modération : Attention a ce que cela ne dérape pas trop, jusqu’à maintenant on a pas eu besoin de tempérer et les échanges ont toujours été respectueux donc merci d’essayer que cela reste comme cela, je n’aimerais pas a avoir besoin de faire de la censure, ce n’est pas du tout dans notre esprit …

MultiPlus-II 48/5000 + Enphase IQ7 : Frequency Shifting, ESS et zéro injection réseau

Les consignes de limitation de puissance n’étaient pas transmises à mes MO depuis mon Envoy Standard (firmware 08.03.5422, sans compteur). En l’absence de CT ( Envoy-S Standard non-metered), le logiciel de l’Envoy détecte 0 phase, alors que mon installation est monophasée. Cette valeur erronée empêche le programme chargé de transmettre les consignes de puissance par CPL d’exécuter la boucle d’envoi des commandes aux micro-onduleurs. Résultat : aucune consigne de limitation ne leur est…

MultiPlus-II 48/5000 + Enphase IQ7 : Frequency Shifting, ESS et zéro injection réseau

nicolas: The revision dated 1 September 2026 stated that the PV power connected to AC-out had to remain less than or equal to the continuous power at 25 °C, i.e. 4,000 W for a MultiPlus-II 48/5000. The current page, dated 2 November 2026, refers once again to the nominal power in VA I’m no expert, but it occurs to me that the factor 1:1 rule should be interpreted as an equivalence between two equipmements. Perhaps it doesn’t matter if values are quoted in Watts or VA as long as both pieces of…