DigiKey TechForum - An Electronic Component and Engineering Solution Forum - Latest topics

Latest topics

SA404A alternative

Hello, We are currently using the SA604A IC in our products. However, based on the information provided by your team, this IC has been discontinued. I would like to know if there is a recommended replacement for this device. If no direct replacement is available, could you recommend an integrated circuit suitable for HDX demodulation? Thank you in advance for your assistance. 1 post - 1 participant Read full topic

Technical Inquiry and Availability Request for STEVAL-16GZMAI1 Camera

I have some technical questions: 1. VIS and NIR Operating Modes Does the camera support independent operation in Visible (VIS) and Near-Infrared (NIR) modes? Is it possible to switch between VIS and NIR modes through software commands without restarting the camera. 2. Frame Rate and ROI Configuration What is the maximum achievable frame rate (FPS) at full resolution? Could you provide a table of supported ROI resolutions and their corresponding maximum FPS? Does reducing the ROI size increase…

LTE Cat 1 module with built-in eUICC that can download consumer (SGP.22) eSIM profiles?

Hello, We build an e-bike telematics unit (ESP32 + LTE module) in Nepal. Our local operator gives IoT SIMs only as a consumer eSIM with a QR code (SGP.22, SM-DP+ address + activation code). Our current modems (SIMCom SIM7600E, Quectel EC20) have no eSIM inside, so they cannot use it. We are looking for: An LTE module with a built-in eUICC that can download and enable an SGP.22 profile from a QR code / activation code, using AT commands (no phone, no app). Bands: LTE B3, B8, B20, plus 2G…

Clarification on Overall Cable Length for StarTech Cable HDMIEXTAA6IN

If you are wondering about the overall cable length for HDMIEXTAA6IN from StarTech.com, please note the following: The 6 in (152 mm) specification refers only to the cable portion of the assembly (as shown in the drawing below). The overall product length, including both the cable and connectors, is approximately 258 mm. This dimension is also specified in the product datasheet. Applicable Part Numbers (click for more details) 1 post - 1 participant Read full topic

Requesting new part numbers for SiT8008

Hello, please create Digi-Key part numbers for the following SiTime SiT8008 oscillators: SiT8008BI-22-33E-36.000000 SiT8008BI-22-33E-37.000000 SiT8008BI-22-33E-38.000000 SiT8008BI-22-33E-80.000000 SiT8008BI-22-33E-110.000000 These should match the existing SiT8008BI-22-33E-50.000000 configuration: 3.2 × 2.5 mm, ±25 ppm, 3.3 V, output enable on pin 1, industrial temp (-40 to 85 °C). Please use whatever packing suffix applies for small quantities. Thanks, Lucas 2 posts - 1 participant Read full…

M83513/01-BN Mil Spec vs Manufacturer Part No

I’m looking for a Micro D-Sub connector that adheres to Mil Spec M83513/01-BN. I was looking at the one made by ITT Cannon, LLC, which looks like the correct one, however the manufacturer part number that DigiKey provides is just the Mil Spec number, which appears nowhere in the provided datasheet as a decodable part number. I would like to make sure I am ordering the right part. Here is a link to the part: https://www.digikey.com/en/products/detail/itt-cannon-llc/M83513-01-BN/4803575 Can…

8 established top brands of LAPP covering specific areas of cable, connection & automation techno

8 established top brands of LAPP covering specific areas of cable, connection & automation technology Brand Product Group / Area Typical Applications ÖLFLEX® Control and connection cables Machine and plant engineering, drag chains, robotics, power supply Unitronic® Data transmission systems & fieldbusses Electronics, low-frequency, sensor and fieldbus applications ETHERLINE® Industrial Ethernet components Industrial networking, PROFINET, high-speed data transmission EPIC® Industrial connectors…

Tech tip: How to size a 230 V online UPS (1 to 3 kVA): power rating, batteries and backup time

A single-phase online UPS protects IPCs, HMIs, network equipment and small machine controls against power outages and mains disturbances. With double conversion the load is always supplied by the inverter, so there is no transfer gap when the mains fails. This tip shows how to size the Wöhrle AC-UPS-PS-230 series (1 to 3 kVA). It comes in two versions: -B with internal batteries, ready for connection, and a version without batteries that you equip yourself. 1. Determine the load Add up the real…

WEB – feedback to LAPP from CH – Confoederatio Helvetica!

WEB – feedback to LAPP from CH – Confoederatio Helvetica! Question online 2026-06-09 from Switzerland: Why cable length per foot? I have feet and they are perfectly fine. I don’t need more. I need cables in meters. This is Europe after all. Let’s go. At least have a way to switch between metric and silly English way. Thanks. Chip chip cherry-o. Get into the lory, what ever that is. And which king’s feet anyway? Were they hairy? Maybe with warts? Did they measure those too? Silly. Meters Please.…

Key Tech.Concepts – What U Need 2 Know about cables - 5 critical engineering factors + brands

Key Technical Concepts – What You Need to Know about cables - Five critical engineering factors + brands of LAPP - EPIC®! SKINTOP®! ÖLFLEX®! ETHERLINE®! UNITRONIC®! 1. Cable Type Abbreviations (The German Norm) Most LAPP cables use standard German/European letter codes printed on the outer jacket (e.g. ÖLFLEX® CLASSIC 110 3G1.5): 3G1.5: 3 conductors, 1.5 mm² cross-section. The “G” stands for Grün-Gelb (includes a Green-Yellow ground wire). If it says 3X1.5, it has no ground wire. Y: PVC…

Flow Meter Calibration

I am working on a Water Flow Test Stand at the University of Southern California. We are considering the ifm SU8621 flow sensor for installation in a nominal 1-inch water line and would appreciate your guidance on calibration and suitability for our application. Our system uses compressed air to pressurize a water tank, driving water through a control valve, past a pressure measurement point, and through a test article. Only water flows through the sensor. We use volumetric flow rate and the…

Help Identifying Sony 24-Pin Multi Interface Shoe Connector

Hi everyone, I’m trying to identify the manufacturer of this 24-pin connector used in Sony’s Multi Interface (MI) Shoe system. The connector is used on accessories such as the Sony XLR-H1 audio handle, as well as compatible audio adapters from DJI and Insta360. It features exposed electrical contacts integrated into a moulded plastic housing, with an FPC connection. I’m looking to source the connector itself, ideally as a standalone component rather than purchasing a complete replacement…

WAGO PCB Terminal Block

I am contacting you here on behalf of Geaux Robotics to inquire whether a product variation can be made available for order. According to the official WAGO Corporation website, 2606-1101 is available in a red-and-black variation. Additionally, 2601-1104 can be made in an alternating green-and-yellow variation. Now, after emails and communication, this is something we must acquire through a distributor. So I am reaching out here to see if this can become an option on the website or something we…