D
If you are looking for an alternative to Motorola HEP Z0411, 8.2V 1W zener diode, I found 1N4738A-ND from onsemi. I found the specs for Z0411 on this catalog. Please review onsemi’s datasheet to verify it will work for your application. 1 post - 1 participant Read full topic
D
For iPad 11 3rd gen around the charging port. Got a link for this little guy? 1 post - 1 participant Read full topic
D
Since 23 November 2026 the DigiKey website is unusable on my windows PC, in my office, for my business, in both Firefox and Chrome. The web site that is served out to me is text only with hyperlinks, which looks like it is from the 1990s, but none of the links work. The only way I can use the site on my network is on my iphone using Safari, otherwise in order to use my PC I have to force the iPhone into a cellular connection, make it into a hotspot, and use this connection for the PC. This…
D
There isn’t a calibration process for the CM410, because Transforming Technologies says it’s factory calibrated and fixed. Transforming Technologies recommends checking that the monitor works with the CM410PV periodic verification unit, at least once per year if your quality program requires testing. Calibration Verification Statement 1 post - 1 participant Read full topic
D
For sites with no Ethernet (wellheads, pump stations, irrigation controllers), here is how to get a serial device online over LTE with the Connect EZ 4i Industrial Kit with Cellular (EZ04-IAG4-EXT). What you need EZ04-IAG4-EXT. The kit includes the Digi CORE plug-in LTE modem, two LTE antennas, a 2.4/5 GHz Wi-Fi antenna, an Ethernet cable, an extended-temperature power supply, and a DIN rail clip. The DIN rail bracket (76002093) is sold separately. An active LTE data SIM in mini-SIM (2FF) size,…
D
Trying to find a proper category in product listings for what I have only ever seen referred to as a “Hook” solder terminal. They come in many IPC training kits. I can find a TopLine product listed via Google that matches what I’m looking for, but it does align with any search results. I’ve attached a PDF of the first page of their product listing. Hook_Terminal_105000.pdf (191 KB) Can anyone point me in the right direction? 2 posts - 2 participants Read full topic
D
A valve terminal at the end of a 30 m cable often gets much less than 24 V. This tip shows how to calculate the drop on a 24 V DC cable, choose the cross-section and decide when to raise the output voltage of the DIN rail power supply. Key takeaways Calculate the loop, not one wire. ΔU = 2 × L × I / (κ × A): 30 m of 1.5 mm² copper at 6 A drops about 4.3 V. Warm cables drop more. Copper resistance rises by about 0.4 % per kelvin, which adds about 12 % at 50 °C. Cross-section first. 2.5 mm²…
D
A typical question from cabinet builders: the 24 V supply runs well below its rating, so why does it hit its current limit right after a power outage? Often the battery charging current of the DC UPS is missing in the sizing. This tip shows how to include it, using the Wöhrle UGS2420 DC UPS controller. Key takeaways The charging current is a continuous load. The UGS2420 charges with constant current (0.75 to 3 A) for hours after an outage. Size for the moment mains power returns. Add buffered…
D
Key takeaways The CONVERT II 6 kVA and 10 kVA units have no built-in batteries. They always run with a battery module. Full-load autonomy with the module is 7 minutes at 6 kW and 4 minutes at 10 kW. Check the power rating first, then the autonomy. Use full-load times as the conservative basis. A UPS for a control cabinet has to meet two limits: the rated power and the time it can bridge a mains failure. This tip shows how to check both for a cabinet with a PLC, an industrial PC and network…
D
I am presently using some pogo pins in a project, the only part numbers I can find are P75-J1 and P160-J1 from the usual far Eastern suppliers, for example https://www.aliexpress.com/item/1005006623692196.html I would love to find a western supplier for these, ideally with a more comprehensive datasheet than just the dimensions on that web page! I have scoured the Mill-Max and Harwin catalogs to no avail, does anyone have any other suggestions? Thank you. 3 posts - 2 participants Read full topic
D
Need help finding a backshell for ms24266r14b15p7 2 posts - 2 participants Read full topic
D
------Question for FZ600R12KS4HOSA1 Please Put your question below------ Packing is tray, how many piece on the tray? 3 posts - 3 participants Read full topic
D
I created my Scheme-it account around April 2026, and I had about 3 projects saved. Recently, I couldn’t log in because the system said my account didn’t exist.Could you please help restore them to my account? 2 posts - 2 participants Read full topic
D
------Question for AB420 Please Put your question below------ 2 posts - 2 participants Read full topic
D
(topic deleted by author) 1 post - 1 participant Read full topic
D
------Question for 24408 Please Put your question below------ Is the SPARKFUN THING PLUS - ESP32-S3 is both adaptor and battery operated ? 6 posts - 2 participants Read full topic
D
Hello, I am looking for the carrier tape and reel specification of the STMicroelectronics M24C02-RDW6TP (2-Kbit I2C EEPROM, TSSOP-8, DigiKey part number 497-18720-2-ND, Tape & Reel). I could not find these details on the product page or in the datasheet. Could anyone from DigiKey or the community help with the following? Tape width (W): Tape pitch (P1): Pocket size (A0 x B0 x K0): Reel size (diameter x width): Quantity per full reel: I understand it is 4,000 pcs, please confirm. If there is an…
D
------Question for MCP3564RT-E/ST Please Put your question below------ Where can I find the default SPI address for the 20-TSSOP package of the MCP3564RT chip? The datasheet does not specify how to read the address for the non-UQFN package. Here is a picture of the markings on the chip I have: Thank you! 3 posts - 2 participants Read full topic
D
The top portion is all text-based. I can only guess that the button under the search field is the search button, and clicking that does nothing. I have to hit Page Down about 20 times to get past the product category navigation tree. I have white-listed digikey dot com in my chrome browser, I have deleted all cookies from digikey dot com and digikey.in (I’m in the US, but somehow I got the India site without my directing it to do so), disabled VPN, no ad-blocker. Also tried Firefox, got the…
D
Panduit provides a large array of different physical infrastructure products and tools, which include their BlackFin series of powered hand crimp tooling. We’ve gotten a number of questions concerning calibration certification for these products; do BlackFin tools ship with calibration certs, and if not can they be requested? BlackFin products such as CT-3001/STBT by way of example include a calibration checklist in their instruction manuals. The manual for the CT-3001/STBT can be found Here,…
D
I-PEX now provides Signal Integrity reports for CABLINE, MHF, EVAFLEX & NOVASTACK products right on their web page. Touchstone data is also available for downloading. Just view the product and select “Signal Integrity Data” under the Download section. 1 post - 1 participant Read full topic
D
------Question for 0192860117 Please Put your question below------ Does this crimper come with guarding or is there guarding available? 2 posts - 2 participants Read full topic
D
------Question for D38999/26TA35PC Please Put your question below------ Does this part from Air Electro Distribution come with a CofC fully traceable to OEM? 2 posts - 2 participants Read full topic
D
On 100 to 120 V grids from the Americas to Japan, many sites see more sags than blackouts, and standby generators drift in frequency. This tip shows how the Wöhrle AC-UPS-PS-120 online UPS (1, 2 and 3 kVA) handles both and what to set before commissioning. Key takeaways The load limit falls with the line voltage. Full load needs more than 90 V AC, although the input accepts 55 to 150 V AC. Size for the lowest measured voltage. Below 70 V AC a 2 kVA unit carries only 800 W from the line. Widen…
D
A common question in panel building: the cabinet is fed with 3 × 400 V without a neutral conductor, and the 24 V control circuit needs 15 A. Which input type fits? This tech tip compares three Wöhrle 24 V / 20 A units: the single-phase EF2420, the wide-range ZPNW2420 and the three-phase DF2420. Key takeaways No neutral, no single-phase unit. The EF2420 needs L and N and accepts 90 to 264 V AC (Table 1). Three-phase input cuts the line current. At full load the DF2420 draws < 0.85 A per phase at…
D
------Question for IWR6843ISK Please Put your question below------ 目前開發環境是WINDOW,具備USB及網路PORT,需求是能用這兩個介面讀取資料 1.這個模組是否能夠讀取目標的球座標參數(R,THETA,PHI)也就是目標距離,目標的水平角度,目標的垂直角度(或是目標的高度參數),如果能偵測XYZ座標也可以後段軟體進行座標轉換,我的專案內容需要精確的偵測這個物體(目前是無人機,或是無人機夾帶金屬物體增加RCS)在雷達的什麼方位,距離多遠。 1.1因我先前已有採購其他模組,我買到的是原廠文件中描述具有水平與垂直天線掃描角度與能力,但透過軟體擷取數據輸出時原廠只有提供距離跟水平方位角,並沒有垂直方位角或垂直高度資訊可以讀取,所以想請您協助確認 1.2如果具有3D資訊,是否能提供一下原廠文件確認具備相關的數據輸出能力。 2.原廠是否有支援範例程式(PYTHON或C語言等等) 3.我是否需要額外採購板件達成我的專案(譬如測試卡板)? Our current development environment is…
D
------Question for AO469 Please Put your question below------ what is the electrical rating/certification of this product? I need soldering stations for students, but they need the proper rating for Canada. 2 posts - 2 participants Read full topic
D
What are the Cable O.D.'s for the following parts ? 5073-DP20Z-MM-BLK-3M-ND 5073-DPCAMM-3-ND 5073-DP20P-MM-BLK-3M-ND 5214-DP14MM3M-ND 5073-DPA00003-3M-ND 3 posts - 2 participants Read full topic
D
Good morning, I’m interested in the SiTime SiT8008BI-82-33E, programmable Oscillator. You’re showing stock of XX.XXXX frequency. Are these available for purchase and do you program these according to our required frequency? 2 posts - 2 participants Read full topic