Ect: LEA-M8T – Product Label and Version Identification

LEA-M8T – Product Label and Version Identification We are experiencing an identification issue with the LEA-M8T module. According to the manufacturer documentation, there are two variants: LEA-M8T0-10: Flash FW 3.01 / TIM 1.10 LEA-M8T1-01: Flash FW 3.01 / TIM 1.12 However, the supplied product label does not clearly show the complete type number (0-10 or 1-01). Therefore, the customer cannot verify the exact product variant and has not accepted the material. Could you please clarify: Should the…

XP Power DC-DC convertor AG10N-5 availability

Hello, I am trying to source XP Power AG10N-5 DC-DC converters (2 units). At the moment, I cannot find this part available on the DigiKey website. Could you please advise whether DigiKey expects to stock this item in the future? If so, is there any estimated timeframe when the part may become available for order or backorder? Thank you in advance. 1 post - 1 participant Read full topic

ED-CM4SEN-1432-4C(US) in 100M Ethernet port or 4G module

Hello, I am interested in purchasing the product ED-CM4SEN-1432-4C(US), DigiKey part number 4555-ED-CM4SEN-1432-4C(US)-ND. I understand that this product has some known bugs, one of which is the intermittent disconnection of the Ethernet port and the 4G module. However, I also understand that this issue does not affect units whose serial numbers begin with a four-digit value greater than 2536. In light of this, could you please tell me whether the units you currently have in stock for this…

Tech tip: 48 V or 24 V for a DIN rail supply? Cable losses and current per load

When a machine needs 480 W on a 24 V or 48 V bus, the voltage decides the current in every cable. The current sets the cable cross section, the voltage drop and the power lost in the wiring. This tip compares both options using the Wöhrle POWER-TEC 4810 (48 V / 10 A, 480 W) as an example. 1. Current for the same power I = P / V At 480 W: 480 W / 24 V = 20 A, and 480 W / 48 V = 10 A. Doubling the voltage halves the current. 2. Power lost in the cable P_loss = I² × R, where R is the total…

Cuauhtémoc IPN Student Aerospace Team Electronic Components Sponsorship Request

Hello DigiKey team, My name is Angel Olvera, and I am the Captain of Cuauhtémoc IPN, a multidisciplinary student aerospace team from the Instituto Politécnico Nacional (IPN), Mexico. We are currently developing our flight system for the AAS CanSat Competition 2027, based on a compact PocketQube architecture with custom avionics, embedded software, telemetry, navigation sensors and a portable Ground Station. Our avionics development has now reached the primary component-selection stage. Our…

Analog Devices ADPA9002ACGZN overview

ADPA9002ACGZN is a gallium arsenide (GaAs) pHEMT MMIC power amplifier from Analog Devices that works from DC to 10 GHz. It’s a cascode distributed design aimed at military and space and test instrumentation uses. Key specs (typical): Gain: up to about 15 dB, depending on the frequency band OP1dB: 29 dBm Saturated output power: about 31 to 31.5 dBm OIP3: up to 43 dBm Noise figure: about 3 to 5 dB Supply: 12 V (10 to 15 V range) at about 385 mA quiescent current Impedance: 50 Ω matched at both…

Microchip Technology, PICKit 5 Programmer PG164150: "Device Not Recognized" Recovery?

Microchip Technology offers a huge catalog of semiconductor products, among which is the PG164150 PICKit 5 programmer. Sometimes folks will obtain one of these kits and have issues with their PC not recognizing the device and contact us to seek a replacement for a damaged board. While this can be caused by defects, it’s often much easier to solve than replacing the entire kit. Per Microchip’s article base on working with the PICkit 5, you can follow the following steps to reinstall the device’s…

Analog or digital switch for accessing an audio codec

Hello , I want to use audio codec wm8994 or wm8904 by two masters. When i say use i mean accessing the output of a codec (not controling which is done by i2c ) , i am thinking to use a switch ( analog or digital switch)so that only one master ( MCU) can access it. Can you please suggest a small switch part number? I read the datasheet and found that for wm8994 there is no need of switch as it can take two outputs but for wm8904 we may have to use. please comment and suggest with a suitable part…

Inquiry Regarding HS Code and Availability in Korea

------Question for NPORT 6150-G2 Please Put your question below------ I would like to inquire about the following regarding the product. 1. HS Code Verification and Invoice Revision As this product is intended for use as a component of semiconductor manufacturing equipment, could you please confirm whether HS Code 8486.90-2010 is applicable? If applicable, please also confirm whether you can issue a revised invoice reflecting this HS Code and the corresponding product description. 2. Product…

RS Part Number 8966949

This post is for informational purposes only. Please review the manufacturer documentation before purchasing any recommended parts. Model number 8966949 from RS PRO is an industrial hour counter that we do no carry at this time, however I’ve found that part number 966-99793810N-ND, made by Crouzet, is a good alternative based on the manufacturer specifications. The datasheet for the alternative part can be found linked here: Electromechanical Counters (EN) 1 post - 1 participant Read full topic

CAN Transceiver Product Portfolio Comparison of Microchip

CAN Transceiver Product Portfolio Comparison of Microchip Feature ATA6560/62 ATA6561/63/66 ATA6564 ATA6565 ATA6570 ATA6574 ATA6571 Dual CAN Standby Mode P P – 2x P P P P Silent Mode P – P – P P P I/O pins from 3.3V to 5V – P P – P P P DC voltage at CANH, CANL -27/+42 V -27/+42 V -27/+42 V -27/+42 V -27/+42 V -27/+42 V -27/+42 V SPI – – – – P P – HV- WAKE input – – – – P P P Watchdog – – – – P P – INH- output – – – – P P P CAN FD (5Mbit/s) P P P 2x P P P P CAN PN – – – – P P – Wake up pattern P…

Top 11 FAQs on ADI’s AD5706R, AD5770R, LTC2662 & LTC2672 low-noise, 4-channel, 16-bit DACs

Top eleven Frequently Asked Questions on Analog Devices’ AD5706R, AD5770R and SoftSpan™ series LTC2662 & LTC2672CUH-16#PBF low-noise, four-channel, 16-bit Digital-to-Analog Converters (DACs) designed to generate programmable current outputs Q1: What is the suggested power-up sequence for the AD5706R ? A1: There is no recommended power-up sequence required for the AD5706R Q2: Can I externally connect channels together in current source mode to increase current delivered to the load? A2: Yes, any…

Tech tip: How to integrate a 24 V PCB mount AC/DC module: fuse, inrush, hold-up and layout

Encapsulated AC/DC modules supply 12 V or 24 V directly from the mains on a PCB, for example in control units, sensors or metering devices. Whether the end product works reliably also depends on the input fuse, the inrush current, the start-up behaviour and the PCB layout. This tip goes through these checks using the Wöhrle WPR-30-24 (24 V / 1.25 A, 30 W) as an example. 1. Check the operating point Input: 90 to 264 V AC, 47 to 63 Hz. Operating temperature: -30 °C to +85 °C with derating. Read…

Tech tip: Line-interactive or online UPS? Choosing a 230 V AC UPS for IPCs and controls

A single-phase AC UPS protects IPCs, HMIs, network devices and small controls against power failures. The first decision is the topology: line-interactive or online double conversion. Both bridge an outage with a battery. They differ in what the load sees in normal operation and at the moment the mains fails. This tip compares the two using the Wöhrle UPS SimpLi series (line-interactive, 600 to 1500 VA) and the AC-UPS-PS-230 series (online, 1 to 3 kVA). 1. Understand the difference…

Tech tip: Sizing battery capacity for a 24 V DC UPS

Hi everyone, when dimensioning a 24 V DC UPS, the question we hear most often is: “How many Ah do I need for X minutes of backup?” Here is a simple way to estimate it. Required energy (Wh) = load power (W) x required runtime (h) Battery capacity (Ah) = energy (Wh) / 24 V / converter efficiency / usable depth of discharge Example: a 200 W load with 1 hour of runtime, 90 % efficiency and 50 % usable depth of discharge: 200 Wh / 24 V / 0.9 / 0.5 ≈ 18.5 Ah Add a reserve for aging and temperature,…

Syntiant V2S200D Flex (KAS-700-0177) and KC20074-A01 – Compatibility, Pinout & FFC Orientation

Hi, I’m planning to purchase several Syntiant components and would like to confirm their compatibility and wiring requirements before placing an order. Products under consideration: KAS-700-0177 – V2S200D on Flex KC20074-A01 – Syntiant Flex Adapter DigiKey P/N: 6017-KC20074-A01-ND KAS-33100-0011 – V2S200D Lite Evaluation Kit My plan is to use the Lite Evaluation Kit for initial signal acquisition via USB, then interface a standalone V2S200D Flex sensor with an Arduino Nano 33 BLE Sense Rev2…