V
I’ve been reading a few discussions here about MultiPlus units running hot, and it got me thinking about thermal inspections. I use a thermal camera for electrical work, mostly to check for hotspots around connections and breakers. But I haven’t done much with Victron equipment. For those running MultiPlus inverters or MPPT controllers, do you check them with a thermal camera? I’m curious how you tell normal operating heat from something worth investigating. Do you mainly look at the…
V
Never had this happened before. So when we switch off MultiPlus 48/20000/250-100, using the toggle switches on the inverters, the next day we come back, switch the toggle back on, but the inverters still OFF. Checked all terminations, checked presence of 48V voltage, all good. Then we find that the Cerbo GX MK2 v3.85 automatically had the mode as OFF. Nobody touched that. Very weird. Is this a glitch? Anyone else experience this? What’s the solution? 6 posts - 3 participants Read full topic
V
With a 12V starter and alternator and 24V LFP “house” battery bank, the XS1400 set to charge from the 12V to the 24V side, will the emergency charge function operate correctly from the 24V battery to charge the 12V starter? It would be great if this reverse charge scheme could be set up to act as a battery maintainer as well as the emergency charge function. 2 posts - 2 participants Read full topic
V
I have a 10 year old Sprinter van and am slowly trying to upgrade the system components without a ton of rewiring, tearing open panels, dropping tanks etc. I’d like to use the existing sensors on my fresh/gray/black tanks to display through the Cerbo GX. The van manufacturer (Roadtrek) said the sensors are “traditional 4 sensor system from KIB”. Is there a way to utilize these sensors with the Cerbo GX (with the GX Tank 140 accessory if needed). Would appreciate any guidance from the community.…
V
I’m looking into the install of the Multiplus II 24-5000 on our sailboat. I am uncertain of the ground wiring. Does the diagram below look correct? (At the breaker panels all grounds are tied together) The top breaker panel is shore only, the lower is either shore or Inverter. The inverter is not planned to be used as a shore power pass through when on shore power, except the rare case of using it to charge the batteries. (I do have another charger that can deal with the crappy power here..…
V
Hi Everyone, A couple of years ago I wrote here asking if anyone had experienced weird behaviour on their Cerbo/VRM, where sometimes Essential Loads would not register any load, even if loads were connected and consuming power. This week, my setup started measuring Essential Loads again, out of the blue. I have made no updates on my Cerbo for a few months, and the only thing I have noticed is that my MultiPlus now shows a blinking “Inverter” light, as it did back when it was registering…
V
Can the AC current sensor (CSE000100000) be wired into a Cerbo GX? I need sensing on multiple (19) 120V circuits. I would like to keep this all integrated and networked into the Victron ecosystem. I think I can use 7 of the VM-3P75CT Energy Meters and just read the data per leg. But that seems suboptimal, and overkill. I was hoping to use the single leg AC current sensors, but the datasheet only has them as able to be connected to a MultiPlus or Quattro. Also willing to use non-Victron system,…
V
Is it possible to change the the BatteryLife [BL] Upper Limit (victron documents says 85% default) or is it hard coded? I have used BL to increase my LFP Battery SoC from 20 to 60 in the last time. The BL “function” -discharge disabled- if the BL limit is higher than the current SoC work as I want. But now I dont want to go to higher SoC levels (85%), so I must disable BL. 3 posts - 2 participants Read full topic
V
I have two Multiplus II 5000/48 (in split phase) running to my house as backup. No grid input as this is off grid for other purposes. Per my electrician who wired the back up switch (simple 3 pole switch that switches L1, L2 and N), it should be treated like a generator with a shared ground but everything else is switched. However, should I disable the neutral ground bond in my inverters and just rely on the main panel neutral ground bond when I’m using it as house backup? If so, then what…
V
Beste Forum leden. Ik heb iets opvallends vastgesteld bij het aansluiten van de Victron VM-3P75CT-netmeter. Ik heb de meter netjes voor de AC in van de Multi rs 6000 geplaast. (als netmeter) Alle verbruikers zitten achter (na) de mulri rs (3 stuks 3 fase) Wanneer de VM-3P75CT is aangesloten en als Grid Meter is ingesteld, wordt in VRM rechtsboven bij de AC-belasting het AC-symbool rood weergegeven, met een uitroepteken erbij. Wanneer ik de netmeter uit de installatie haal,(uit zet) wordt…
V
Mooi Blauw is niet lelijk !!! Na in ons oude huis een mp2 met 10 kwh te hebben gehad was het tijd voor een upgrade in ons nieuwe huis Alles werkt als een ‘‘Blauwe trein’’ op een paar puntjes na. 1 post - 1 participant Read full topic
V
Hallo Ich habe mein ESS system um einen Mppt 450 / 100 erweitert und warum auch immer wird die batterie jetzt nur noch bedingt vom Multiplus geladen ( siehe grafik ) die Maximale Ladeleistung von 3600 Watt wird nicht erreicht ich verstehe nicht warum das so ist… 1 post - 1 participant Read full topic
V
beste forum leden !!! Na weken speuren, lezen en proberen ben ik er helemaal klaar mee. Ik krijg het niet voor elkaar om de ess te laten werken zoals het bedoelt is (volgens mij) De overtollige PV stroom zou in de accu moeten gaan nadat het net op 0 staat zeg maar. Mijn Probleem is als volgt: De SOC van de Accu staat op 75% ESS staat op geoptimaliseerd zonder batterij life Een voorbeeld uit VRM: PV-opbrengst: circa 2.105 W Woningverbruik: circa 276 W Accu laden: circa 2.004 W Netafname: circa…
V
Hallo Victron-Freaks, kennt mittlerweile neben Fronius noch jemand weitere Wechselrichter, deren Ausgangsleistung ein Multiplus II mittels Kommunikation am AC-Out steuern kann? Die Notwendigkeit der Steuerbarkeit (ohne Frequenzregelung) sehe ich beispielsweise bei einem ESS-System mit Nulleinspeisung. Sobald die Ausgangsleistung des Wechselrichters am AC-Out die Ladeleistung des Multiplus II übersteigt (z.B. bei voller Batterie) müsste ein am Netz hängender MP II den WR an AC-Out anweisen, die…
V
Hi everyone, We recently handed out more than 100 of the first BMV-812 units at the Victron distributor meeting, and I thought it would be nice to start a conversation here. The goal with the BMV-812 was to make a modern successor to the BMV-712 with a full-colour touchscreen. It’s a drop in replacement no need to update wiring or the shunt. These first units are running beta firmware. We are working hard to make the firmware feature complete for the first stable release. Historical, trend data…
V
Fellow members, when posting code that has used AI to generate it, please follow our labelling guidelines found here: Labelling AI generated code and flows Node-RED While our guidelines don’t permit AI content, it is near impossible to manage that in the dev world. We’re seeing a huge increase in personal projects being posted as a result. Industry norms are increasingly moving towards declaring content as having used AI so people can make their own choices about what they want to use. While…
V
While our guidelines don’t permit AI content, it is near impossible to manage that in the dev world. We’re seeing a huge increase in personal projects being posted as a result. Industry norms are increasingly moving towards declaring content as having used AI so people can make their own choices about what they want to use. While AI-generated posts will continue to be moderated and asked for review and rewording, please ensure any code is labelled as using AI. Our flow renderer syntax still…
V
Hello everyone, I’m trying to connect four Fronius inverters at an installation in Lochem to a Victron Cerbo GX so that their data can be monitored. The Cerbo GX does not detect the inverters when I run a scan. I connected a laptop directly to the Datamanager and accessed 169.254.0.180. The web interface opens, but it requires a username and password. The customer no longer has these credentials. I also contacted the company that installed the system, but they could not help with the login…
V
I’m experiencing a strange issue on a remote off-grid installation using: Cerbo GX MK2 GX Touch 50 MultiPlus-II 48/5000/70-50 SmartSolar MPPT 250/70 Lithium battery bank Last week the system experienced a MultiPlus overload condition (red overload LED). The site was recovered by: Turning OFF AC load breaker. Turning OFF MultiPlus inverter. Turning OFF DC breaker. Waiting a few minutes. Turning ON DC breaker. Turning ON MultiPlus. Reconnecting AC loads. After the restart, the power system is…
V
Mismo problema para mi. Y Victron me borra el mensaje de ayer… Mala señal. Tengo el EV conectado correctamente a un Quattro 48v/8000 y Ground relay activado. La toma de tierra esta a escasos 5m del inversor. He probado de todo y el EV sigue dado error de tierra… Version del EV: 2.09 9 posts - 3 participants Read full topic
V
Hi all, I’m looking for a way to set ‘0-on-the-meter’ for Multi RS Solar set-ups with DC coupled PV. The setting in the screenshot works very well to achieve this, but I don’t find a way to set this parameter in nodered. There’s a lot of options in AC system control, system settings custom control and even Dynamic ESS nodes that refer to the feed-in, but none seem to have any effect. Perhaps anyone has a tip If not, perhaps someone from the Victron team can take it along as a feature request. 7…
V
Salve a tutti, ho collegato il Blue Smart IP22 Charger 12/30 Output 230V alla nuova batteria al litio della LiTime da 320Ah. ho settato il tipo batteria come Li-ion, ma vedo che dal IP22 carica la batteria alla tensione di 14,20V. con appena 5,9A. in funzione di Assorbimento. poi passa in funzione Stoccaggio quando ancora la batteria è al 61 % di carica e l’IP22 cessa di erogare corrente. Qualcuno può darmi qualche spiegazione ? Grazie a tutti. 2 posts - 2 participants Read full topic
V
I did something stupid… I didt save my thing before uppdate. No im having trouble to find correct charger settings. I have 3x200ah 12v Victron Smart lithium Batterys Sorry for a bad picture, but does this look right? Or should i switch to Adaptive instead of Fixed charge curve and is the rest correct? 2 posts - 2 participants Read full topic
V
GitHub - Born2Ski/RpiHotspot: SetupHelper package: Wi-Fi access point (hotspot) for Venus OS on Raspberry Pi · GitHub Feel free to use and test! Report issues on github. Thanks 1 post - 1 participant Read full topic
V
I am at the point that I am going to unhook my batteries and bring them inside for the rest of the winter. So, I will disconnect my panels first then disconnect the batteries with the main battery disconnect switch that’s between the batteries and shunt and remove. In that configuration can I plug in my shore power cord and have it pass through my 24 volt Multiplus ll inverter/charger and power up the inside receptacles? What position would I want the inverter switch in to allow it to pass…
V
Bonjour, J’ai appliqué les paramètres LifePO4 sur le Smartsolar et je m’interroge si j’ai bien fait ou pas pour cette batterie d’occasion qui semble fonctionner correctement. Setup: batterie LifePO4 100 Ah, Smartsolar MPPT 75-15, PV 210 W, pompe 12V 5 A branchée sur Load. Faut il rester sur les paramètres par défaut ou en appliquer d’autres. Le principal consommateur est une pompe 12V 5 A max qui tourne 1H maxi par jour par séquences de 10 minutes entre 10h et 14h, principalement printemps ,…
V
Bonjour a tous, je possède un Multiplus compact 12/1600/70 et je souhaiterais pouvoir régler mon appareil le mieux possible, sauf que je ne sais absolument pas quoi régler ni a quoi tous les réglages correspont. J’ai aussi la possibilité de faire un partage d’écran si ça intéresse pour que la personne puisse me guider. 7 posts - 3 participants Read full topic
V
Hi Everyone, I have a Multiplus-II 12/3000/120-50 2x120v and a Cerbo GX, among other Victron components. Prior to the upgrade to v3.85, I had typical North American breaker sizes under the shore current limit page, e.g. 10,15,20,etc.. After the upgrade, I only see 230v breaker sizes, e.g. 3,6,10,13,16,etc.. Is this a bug or a setting that I can’t find to change these back? I frequently limit shore power from 30a to 10a to force assist and solar usage and back at night. I want to build something…
V
Hallo, kurz zu meiner Anlage: 2 Monate habe ich eine 1 Phasige Anlage mit 32kwh Speicher betrieben als Überschusseinspeiser betrieben. Die Anlage bestand aus einem Multiplus 2 5000, einem Cerbo GX und einem Lynx Distributor. Die Anlage lief Problemlos. Wegen fehlender Ladeleistung (habe 30kw PV auf dem Dach) habe ich jetzt 2 weitere Multiplus 2 5000 nachgekauft und alles umgebaut. Die 3 Multiplus wurden entsprechend auf die 3Phasen angeschlossen und konfiguriert. Grundsätzlich läuft auch alles,…
V
Hallo ich habe zwei MP parallel im Serienbetrieb mit ESS. Das heißt der ganze Hausstrom fließt duch die MP. Nun möchte ich einen dritten ins ve nehmen, dieser soll lediglich Ladefunktion haben ohne am 230V Netz teilzunehmen, dennoch hätte ich ihn gerne in der Verwaltung. Wie geht das? 6 posts - 3 participants Read full topic