Hi, as of Venus OS v3.85/Cerbo GX, there is no support for ‘protected management frames’ on Wi-Fi. The Cerbo GX is locked out of Wi-Fi with mandatory protected management frames (PMF) set up. Enable wpa_supplication with IEEE80211W support: CONFIG_IEEE80211W=y Check runtime support: # strings wpa_supplicant | grep ieee80211w ieee80211w
V
Did you use the correct port? You should connect the VE.Bus one. Just a double check, it’s easy to have it plugged in a different UTP and VEConfig seems to load, but just doesn’t detect anything in the end.
V
professional.victronenergy.com Victron Professional Click on the training link, it’s free and has everything you need to prepare
V
Hallo, AES spart im Inselbetrieb durch die Modifikation der Sinuswelle Strom im Inselbetrieb bei geringen Lasten. Ist die Anlage netzgekoppelt, gibt das Netz die Frequenz vor und die Anlage MUSS sich “unterordnen”. Anders gesagt, die AES Einstellung hat im Netzbetrieb keinerlei Auswirkungen, egal ob aus oder an, ob modifizierte Sinuswelle oder Suchmodus…
V
Damit musst du dich leider abfinden wenn dein MP2 als Insel läuft. Ich betreibe zwei MP2 5k parallel einphasig als Insel (also ohne die Unterstützung vom Netz) und habe mit meinem 3d Drucker dasselbe Problem wie du. Besonders 230v LED Leuchtmittel ohne separates Netzteil sind extrem empfindlich auf die Schwankungen. Aber richtig schlimm ist meine Siebträger Espresso Maschine die dank PID Überwachung die Heizung der zwei Boiler (zusammen 3000W) im Sekundentakt taktet, um die Temperaturen…
V
You may need to go to security and set a password? I believe fw updating resets it.
V
Oui, j’ai vu pour les exigences concernant le local, et c’est prévu pour la batterie. J’ai un emplacement juste à côté du tableau électrique que je peux fermer pour en faire un local dédié. J’avais d’ailleurs laissé suffisamment de longueur de câble entre la batterie et le MultiPlus pour pouvoir la déplacer à cet endroit. Concernant la limitation de puissance Enphase, j’ai bien regardé ta documentation, mais mes essais ne sont malheureusement pas concluants. La commande de limitation est bien…
V
Ik heb inmiddels begrepen dat het bij Victron een bekend probleem is van de ip22 lader. Nu maar hopen de men nog een keer met een oplossing komen.
V
Hola @DB9DH , Tengo una instalación parecida a la tuya. Lo que tengo para cuando se me descargan oas baterías es un Transfer Switch manual, para pasar a alimentar las cargas de la casa desde la red hasta que vuelva el sol. Mi pregunta, tras leerte, es si estoy cumpliendo con los requisitos de aislada al tener cables de red y de inversor conectados al TS, yo entiendo que sí, ya que el tranfer no tiene contacto interno ni con neutro, y para pasar de uno a otro el interruptor pasa antes por zona…
V
When you access it, any passwords on the console itself can be configured via the security profile.
V
Lol, thanks for the big print! I’ll have another look next week when back on site. Cheers.
V
It contains the bluetooth pin and local AP details. Looks like this:
V
I do have some spare stickers but I sure can’t see any P/W or PIN on them, unless I’m going blind in my old age! (Which is quite possible)
V
I will give this a go when I’m next on site, but I have a feeling I have already tried this.
V
No need to remove it. The sticker is on the lower side, opposite the connections. (trunking might be in the way, else check the box it came in, if you still have it, stickers are in the accessory bag).
V
Thank you Hannus, it works over LAN and is connected to VRM but I would like to see it on local wifi or bluetooth like I can with my other Cerbo installations. I think I will have to take it off the wall in search of the password. Thanks for your time guys.
V
Hi @A-P l, no this doesn’t work for all roles. Power factor is logged for the following roles: Grid meter Ac load Genset Heat pump Apparent power is only available for the Grid meter role as far as I’m aware.
V
Was verstest du unter lokales Netzwerk? Wenn Wlan wegen dem fehlenden Paswort nicht geht, dann sollte es aber über Lan noch gehen.
V
The unit ships with separate labels in the box as well as those stuck on it underneath. It is visible. From there you can configure the security profile. Don’t select the network version, just the blueteeth one (lower one on the image).
V
Yes apparently so but I cannot find it on any of the stick-on labels that it came with. I read that the P/W is on a label on the back of the unit (I did not put it there) but as it’s in service and screwed to a wall I am reluctant to take it off on spec.
V
nicolas: J’ai également découvert une piste intéressante concernant la limitation de puissance Enphase. J’ai trouvé la référence à deux registres Modbus : 40310 : Limit Max Power Pct Enable 40311 : Limit Max Power Pct Setpoint Effectivement, lorsque la passerelle est intégrée au GX, ce sont ces registres qui sont utilisés pour réguler la production. C’est d’ailleurs écrit dans la note technique que j’avais ajouté. Je comprends ton dégoût face à cette situation. La perte est lourde et ne sera…
V
The unique BT pin is written on the label that shipped with the device. It shouldn’t ask for a password with a local login from the app.
V
Haha, yes, wish I could but I can’t log-in as it’s not accepting any password including on bluetooth.
V
It always pays to read the manual. Use bluetooth via the app for initial setup, then take it from there.
V
Thanks for the speedy response Nick. A good question which I don’t recall as I set this up some months ago. But I don’t believe that I have ever had to “configure” a Cerbo before - they are pretty much plug n play.
V
Did you configure it first with the victron connect app?
V
Hello all, I cannot log-in on local network to my new version (Mk3) Cerbo GX as the password (which I have not set) is not recognised. I have tried all of the standard default password variations with no luck. I can access via VRM remotely with no problem, any ideas? I have not ever had this problem with earlier Cerbo’s
V
als je ublock hebt draaien dan zou ik daar het eerste gaan zoeken als je niet de app gebruikt..
V
Not adhering to the ccl override is a known issue with 3.80 and pylontech. Already topics open for this. Upgrade to the beta or downgrade to 3.79. It should be addressed in 3.86. You should be able to set this parameter via modbus, sounds like you’re setting something else if it keeps changing (also known behaviour). You can set the DVCC max current limit (but this will be ignored if exporting is enabled and with the 3.80 bug). via MQTT: W/dxxxxxxxxxxxx/se…
V
Merci beaucoup pour vos retours et pour toutes les informations partagées. De mon côté, j’ explore l’intégration de la passerelle Enphase via Modbus TCP afin de récupérer davantage d’informations directement depuis l’Envoy. Pour le moment, la passerelle n’apparaît toujours pas sur mon GX. La communication Modbus fonctionne néanmoins via Python et j’ai réussi à identifier les différents modèles SunSpec. En revanche, je rencontre des difficultés pour lire correctement les registres du modèle 701…