Victron Community - Latest posts

Latest posts

MPPT RS 450/100 and partial shading of a string

Alex Pescaru: Китайське програмне забезпечення MPPT має тенденцію блокуватися та шукати кращу MPP з «лівого» боку знайденої MPP, зменшуючи напругу шляхом збільшення струму. These same two different approaches to finding the point also occurred to me.

Stale Virtual EVs devices on VRM that cannot be cleaned up

Hi, I participated on the Beta for EV, and I wanted to convert it to virtual-EV devices in Nodered. It all seemed to work for a while during development of the node-red flow, but after adding the VIN, Brand and Type it seems to get confused and revived the original beta-EV configuration in the VRM while there is no longer a connection to the car. Even when uploading data to the virtual EV at ID 100 or 101, it turned out to be updating the device with ID 40. It seems to not look at the device…

Orion XS 1400 Feedback and feature request

Over de aansluitpunten is al heel wat gezegd. Ik herken de dingen die je aangeeft wel. Om de schroefjes van het kapje los te draaien kost de eerste keer nog wel eens wat moeite, waarom die in de fabriek zo vast aangedraaid worden?? Er kan ook 25 mm2 aangesloten worden met kabelschoenstiften, wel een krimpkous er over want het zit heeeel dicht op elkaar. Op een non-isolated hoeft er niet zo’n dikke massa kabel aan, die kabel is alleen voor de massa van de orion zelf en gaat maar weinig stroom…

WECO 5K3 EVO – Incorrect battery capacity displayed on Cerbo GX

J’ai déjà contacter le service Weco, je ne reçois aucune réponse de leur part. Autre choses, Mon groupe électrogène peut fournir environ 4,2 kW en continu, mais le MultiPlus-II limite systématiquement la charge des batteries à environ 2 kW (30 A sous 48 V), malgré une limite DVCC autorisant jusqu’à 102 A et une charge AC réglée à 70 A. Lorsqu’une consommation supplémentaire apparaît sur la sortie AC OUT (LOAD), le MultiPlus accepte de prélever davantage de puissance sur le groupe pour alimenter…

What is the benefit of a Lynx Shunt

Du hast recht. Wir weichen wohl zu sehr vom Thema ab. Ich hatte auch einen Shunt eingebaut da ich damit die DC Verbraucher messen wollte. Der hat aber das ganze nur durcheinander gebracht so dass ich ihn nun übrig habe. Vielleicht kann ich Ihn mal wieder reaktivieren wenn ich raus gefunden habe wie man den als einfachen DC-Leistungszähler missbraucht.

Problem mit usv/notstromfunktion weil zu empfindlich

hallo, ich habe das problem, dass bei meinem system, mehrere 3-phasen-systeme hintereinander, die nachgeschalteten system auch dann in kurz den inverterbetrieb wechseln, wenn das garnicht noetig ist. die usv-funktion habe ich schon deaktiviert, trotzdem reicht schon mal das zuschalten von ca. 300W, damit das letzte system auf usv-betrieb umschaltet. dieses problem hatte ich in der vergangenheit nicht. allerdings habe ich dieses jahr einiges umgebaut und dabei die reihenfolge der systeme…

Android GX Display v2.0beta1 available for testing

With a local Cerbo GX (mk2) and logged into VRM it would connect local and take a bit of time loading/compiling, then switch to VRM before it finished. Was always showing VRM on the settings screen connection info. Logged out of VRM it works fine and states “Showing the local GX”. Also having a similar issue switching between local devices. (Not logged into VRM for this.) Second device is a Pi Zero2W v3.90-beta9. Took repeated tries to switch back to the Cerbo. Connection status screen would…

What is the benefit of a Lynx Shunt

Hi @Richardweir77 , danke für deine Antwort. Die Firmwareversion kannst du über das Pylontech Konsolen Kabel oder über VRM-> Geräteliste-> Firmwareupdate herausfinden. Da du zwei verschiedene Akkus hast wird wahrscheinlich nur das erste Akku angezeigt. In der letzten Zeit wurde an der Pylontech Firmware einige Änderungen gemacht die das Ladeverhalten beeinflussen. Die Frage war eigentlich an @dognose mit deinen 16 Pylontech Akkus gerichtet.

3.80 Generatorzustand wird auf Remotekonsole falsch angezeigt

Bei einem Off-Grid System ist im Cerbo für den Generator eine Warm und Abkühlphase von 5min programmiert Beim manuellen Start über VRM fiel auf, dass während der Warmlaufphase in VRM " In Betrieb" aber auf der Remote Console jedoch “angehalten” angezeigt wird. Aufwärmen ist jedoch “in Betrieb” aber nicht durchgeschaltet und nicht “angehalten”, daher müsste es auf der Remote Console auch " in Betrieb" lauten. Des weiteren habe ich seit einiger Zeit beim Aufrufen der Steuerung in VRM das Problem,…

Remote access for VictronConnect App on my phone

While I understand your desire not to add more cables between the various components and a GX device, having a Cerbo GX and consulting the data via VRM gives you the advantage of having a continuous record of all system’s data points for the recent past. I’m in a similar situation with my boat a few hours away in the winter, but having a record over time of the system’s data has allowed me more than once to review this past data and understand what happened when the data at the time of my query…

Ess-problem externe steuerung nach assistenten-update

hallo, ich habe hier ein sehr seltsames phaenomen nach dem update des ess-assistenten im cerbo! das ess ist auf externe steuerung eingestellt, schon vor dem update und als es nach dem update wieder aktiviert wurde, hat das system ca. 9 kW eingespeist, was bei meiner konfiguration bedeutet, von einem system mit mp 5000 an ein anderes system mit mp2 5000 uebertragen, wo dann der akku damit geladen wurde! leider weiss ich nicht, was dieses verhalten ausgeloest hat. eine umstellung auf interne…

Regelverhalten ESS mit v3.85?

ok und nun zur Aufklärung. Definitiv verhält sich v3.85 zu v3.80 anders bei mir. Das aber auch in der visuellen Darstellung und weniger im Regelverhalten. Anscheinend sehe ich es jetzt nur deutlicher im VRM und RemoteKonsole. Das zappelige Regelverhalten war ein Hausgemachtes Problem. Ich habe mehrere Akkupacks mit Victron Shunts. Hier kam es zur Nutzung verschiedener Spannungsquellen und so letztlich zu kleinen Spannungssprüngen im Batteriemonitor. Dass sich solche Sprünge nicht gut aufs…

Trading optimsation at high electry prices throughout the day

I have a 3 phase system (3x MultiPlus-II 48/6k5/100-50) with a 32 (2x16) KwH battery behind it. Yes i know, maybe a bit much for just 32 KwH on battery, but it was installed so that i could expand on battery capacity later without having to upgrade everything… Over the last few days (with high electricity prices throughout the day I noted that the system does not optimise correctly. For example yesterday it pulled 45.2 KWH from the grid (and got 2.1 KWH solar), of which my own consumption was…

EV Charging station V2

Zum Verständnis, die hier gelisteten 813€ sind a) netto b) ohne Bidirektionales Das Modul wird von Lucian schon selbst als teuer beschrieben. Sehe hier schwarz was das Thema Wirtschaftlichkeit angeht. Schade, dass dem PV-Heimnutzer das ganze Thema immer unattraktiver gemacht wird.

Battery balancer for 24 volt

It’s rather going o depend on whether you have them right next together or not. And how long the jump is in-between. I am assuming it is in a small space in the vehicle you have a picture of. If the middle is commoned then one cable will be enough on either one of the batteries. Also make all the battery cables the same length.

Battery balancer for 24 volt

Hi I need to connect four 12-volt batteries to achieve 24 volts, using a combination of parallel and series connections. I am unsure about wires 1 and 2; the product datasheet does not seem to provide a definitive answer. Should wire 1 be used? Should wire 2 be used, or should the “Common” connection only be attached to the first negative terminal? I hope to get some reliable guidance here We manufacture electric cargo trucks, etc. Kind regards Leif

EV Charging station V2

Die mögliche V2H/V2G-Kompatibilität ist tatsächlich das Spannendste an dieser neuen Ladestation. Interessant wäre vor allem, ob diese Funktionen bereits zum Marktstart verfügbar sind oder erst durch ein späteres Firmware-Update freigeschaltet werden. Außerdem wären die kompatiblen Fahrzeugmodelle, die maximale Lade- und Rückspeiseleistung sowie mögliche Einschränkungen bei der Installation wichtig. Hoffentlich veröffentlicht Victron bald ein ausführliches Datenblatt!