Smart Shunt - justieren?

I think the only way to do this via settings is to set the battery Ah a bit lower than reality so the SOC falls faster as the consumed Ah will be divided by a smaller capacity. The charged efficiency factor only affects the current counted during charging. Physically you could file a little bit of metal off the resistance plates on the shunt so it reads a higher current than reality, but it is not something I would do.

Multiplus 2 won't turn on

hatte ich glatt überlesen … Du kannst aber die beiden VE CAN Anschlüsse tauschen … den Mppt auf den 2. Anschluss und den 1. BMS CAN auf 250kbit für den Akku … der 1. BMS CAN hat eine galvanische Trennung was wichtig für den Fall ist, das sich der Akku mal mit dem BMS trennen sollte und sich die Masse über das Signalkabel holen könnte.

Multiplus 2 won't turn on

Steffen: This is the first time we’ve heard about the 450 MPPT … how is it connected to the Cerbo? I mentioned it in my first post. MPPT (upper right) to Cerbo thru VE Can1, deadend plug in other VE Can 1 port. Other blue Victron cable to left is to MP2 and currently unconnected. Other Cerbo connections are to to battery shunt and Cerbo touch screen. Ignore the big pink wire - it’s only temporary to have power and NOT part of the regular setup.

What is the benefit of a Lynx Shunt

dognose: So, after 3 Days of Lynx-Shunt-Operation: I’m already 100% convinced it will be superior than the builtin values Congratulations on the upgrade. Lynx Shunt undoubtedly calculates better than any other BMS, but there are some nuances. Since you’ve spent so much time testing and taking measurements with the Pylontech BMS, don’t overlook our beloved Victron. I’d just suggest tweaking the test scenario slightly. 7-day CHR/DSC cycles between 20% and 80%, without reaching SOC 100%. Day 8:…

Expanding a 12.8V LiFePO4 Solar System Using a DC-DC Charger

Hello everyone, I have an off-grid solar system with a 120 Wp panel, a Victron MPPT 75/10 or 75/15, and a 12.8V/54Ah LiFePO4 battery with a 10A BMS limit for both charging and discharging. I need to expand the system to supply 1,080 Wh/day of AC energy with 3 days of autonomy (3,240 Wh). I’m considering adding a larger LiFePO4 battery and using a DC-DC charger to transfer energy from the existing battery without exceeding its 10A limit. I would also add solar panels and use only one inverter to…

Multiplus 2 won't turn on

So a virtual switch or assistant would be thru the Cerbo connection, right? Not in the MP2 itself? If I leave the MP2 communication unconnected to try to start it, then those things would not interfere, right? I had the communication cable unconnected in previous attempts and it wouldn’t start, but it’s also sat offline and untouched for 2 days.

Multiplus 2 won't turn on

Das verkehrte Protokoll wäre ja nur dann wichtig wenn eine BMS CAN Verbindung bestehen würde. Das aber der MultiPlus 2 nicht eingeschaltet werden kann, könnte an einem programmierten Assistenten oder virtuellen Schalter liegen … Gehen wir mal davon aus, das es einen Assistenten gibt der das Abschalten des Multis bewirken soll und dieser Kontakt ist jetzt nicht belegt … startet der Multi dann ??? … die Frage ist eher in die Runde der Community eventuell ist es ja wirklich ein physikalischer…

Multiplus 2 won't turn on

Steffen: Did the system originally come with an EG4 inverter, and has it now been replaced by a MultiPlus 2 from the same supplier? Were the protocol DIP switches adjusted? OMG! Great eye! No, I did not change the DIP protocol switches from EG4 to Victron when I put in the MP2. Argh! Yes, the system was originally built with the EG4 because that was all I could afford at the time. But I also knew that one day when I could swing it, I wanted an all Victron system. I got the MP2 and MPPT 450 from…

Connecting Vatrer batteries via BLE to Cerbo GX - Success!

Using 2 esps would work with some mods. You’d need to rename the entities to reflect battery #3 &#4 on the 2nd esp. A better way would be to modify the existing code to poll 4 batteries, not 2. The esp opens the BLE connection to bat_1, reads the data and then drops the BLE connection then updates the Cerbo. Then moves onto bat_2 of x batteries. Once it gets to bat_x, it starts over. Theoretically there’s no limit to how many batteries you could poll using just 1 esp. My use case was just 2…

Cerbo gx + webasto + ruuvii

I have not tried it yet but I am motivated because it just snowed here! Thinking about trying to place the relay in before pin 4 on the rotary controller to be able to switch in on/off remotly but leave the rotary dial on the desired temperature setting beforehand so it triggers a heating demand. Any thoughts by someone more knowledgeable? (please see sketch)

Multiplus ladestromsteuerung funktioniert nicht gut

hallo, ich lege nun einmal einen grossen wert auf redundanz, falls mal etwas ausfaellt, ausserdem ist das system mit der zeit gewachsen und wurde dieses jahr eben umgebaut. dass mir dann auch noch die neue firmware unnoetige probleme bereitet, war ja nicht vorherzusehen. auf jeden fall laesst sich der ladestrom ueber die eingangstrombegrenzung und die setpoint schneller regeln als ueber die dc-stromeinstellung oder die bat-parameter. da die letzten config-aenderungen auch nicht gegen das…

Orion-Tr Smart 12/12-18 A

Hannus: Le faible courant qui vient de l’EBL n’est pas dangereux pour le câble. En revanche, le courant que la batterie peut fournir l’est. C’est pourquoi les fusibles doivent toujours être placés près de la batterie, afin qu’un éventuel court-circuit ne fasse pas brûler le câble OK ! Bien noté. Merci. Mais ce matin, grosse déception. En effet, batterie cellule enlevée, j’ai déconnecté la liaison commune (listée précédemment) sur le fusible et ai mesuré chaque fil séparément après avoir branché…

Multi RS Solar and Hoymiles ESS Zero Feed In

Hello, I have a Multi RS Solar (firmware v1.31) with cerbo GX mk 2 (venus os v3.85) and also some hoymiles HMS micro inverter on the AC out. I am On Grid, the Multi RS ESS is configured on “Optimized” with zero feed in. The system is quite simple: everything goes through the Multi RS. The grid is connected to the AC-in, and all the loads are connected to the AC-out 1, so no energy meter needed. In my country, a fee will be charged in the near future for feeding surplus electricity into the grid…

Orion XS 1400 Feedback and feature request

Meet het maar eens na​ Bij een non-isolated moet er massa verbinding zijn tussen de accu’s het liefst met een fysieke kabel. Let wel op dat die kabel bij een voertuig met een intelligente dynamo op het juiste punt wordt aangesloten. Zelfs door camperfabrikanten werd die soms direct op de massapool van de startaccu aangesloten, dan gaat het niet goed