XIO

xWire

Posts from every feed QUEST has found across the web — blogs, news, podcasts, channels and more.

Victron Community - Topics tagged vrm

Topics tagged vrm

VRM Android app login fails with Chrome but works with Firefox

Hi, I am experiencing a login issue with the VRM Android app. When I tap Login in the VRM app, it opens the Victron OneID authentication page in Google Chrome. I can enter my credentials and authenticate, but after login the browser does not return correctly to the VRM app, so the app remains logged out. I tried the following without success: Cleared Chrome cache and cookies Cleared VRM app data Force stopped the VRM app Uninstalled the VRM app Restarted the phone Reinstalled the latest VRM app…

Pompage quattro quand seuil SOC atteint

Bonjour, je cale sur un sujet d’apparence simple : couper l’inverter quand le SOC atteint une valeur basse et le redemarrer quand il atteint une autre valeur de SOC. Je suis en config site isolé, avec une batterie pylontech 2x3500, cerbo GX, et quattro 10000 VA. J’ai tout mis à jour. J’utilise VE config dans l’onglet et dans l’onglet inverter, je sélectionne ma valeur de seuil de coupe et de redemarrage (26% et 34% dans la capture d’écran). L’inverter se coupe bien quand le SOC passe sous les…

OneID Login - 2 Login

I changed my log in to OneID. If I go straight to the OneID login page (PC) it just takes me to info regarding my account etc. To actually log in to VRM, I have to use the original login screen - that takes me to the OneID (login) - then that takes me back to the original login screen but seems to auto login from there and then into VRM. This is silly. Surely OneID should mean one login screen? Anyone? Cheers Paul 3 posts - 3 participants Read full topic

Paramétrage Multiplus

En attendant une installation plus complète, j’utilise mon Multiplus 12/500 comme alimentation secourue en DC pour une station de mesure dans un coin où le réseau électrique est instable. Matériel : Multiplus 12/500 Cerbo GX Batterie Victron SuperPack 12V/60Ah Globalement, ça fonctionne. Je peux me connecter au Cerbo en local ou à distance, avec le portail VRM ou avec l’appli Victron Connect. Par contre, pour la configuration Multiplus, je suis très limité. Dans Victron Connect, quand je vais…

Switching options 48v

Trying to work out best option for switching 48v loads. id like to be able to trigger loads via vrm. Loads I’m trying to connect are: Heating Pad (dump load, attached to hot water vessel): 48v 300w 7a Hot Water unit: 48v 1500w 32a Under floor heating 48v 100w 2a Looking at specs on CerboGX and I/O extender (i currently do not own the extender, but will purchase if needed), but all these loads exceed the maximum current/amperage of the internal relays. So, my current idea is to use the internal…

BUILD LOG - LOTS OF PHOTOS - 64KWH Smart Home Energy Trading System, with solar and heat pump

Hello all! I’ve been building Victron systems for many years in automotive and marine applications. This is my first fixed installation, and it is for my home. I’m an engineer by trade, and I work as dealer support for a manufacturer of CT scanners. Here is the system plan: Here is the system plan: MultiPlus-II 15000/48 2x Seplos Mason 560 32kWh: These are ready-to-go batteries with a great active BMS, 157A rated continuous charge/discharge, 200A max, and a built-in fire suppression system.…

Mystery Consumption in VRM - how to troubleshoot?

This morning VRM showed me 1kW consumption at around 6am. Nothing is connected that could possibly use that. The advanced tab does not show anything like that. How can I trouble shoot this? The system is not grid connected. The sun was not up. DC load is usually about 6W, AC load about 7W. Ekrano GX. Multiplus 1200 12 50. No grid connection (no AC In). MPPT 100 30. SmartShunt 500A monitoring 2x100Ah Volthium LiFePO4 in parallel, connected CAN Bus BMS 500 LV. Everything on the Advanced is…

Setting amps is missing in VRM

Recently, the option to set the current limit in VRM has disappeared. I can only set the inverter state. The amp setting that has always been there is gone. Can I get this back somehow? I think it happened when it changed to 2 buttons for setting inverter state and switch state. It used to be a single button that set the inverter, switches and current. 5 posts - 3 participants Read full topic

Lokale Daueranzeige fuer kleine Victron-Anlagen ohne Cerbo/VRM?

Ich stolpere hier immer wieder ueber Fragen, die indirekt um das gleiche Thema kreisen: Wie bekommt man bei einer kleineren Victron-Anlage eine einfache lokale Daueranzeige hin? VictronConnect ist fuer Konfiguration und Diagnose sehr gut, aber eher geraeteweise. VRM/Cerbo/GX ist stark fuer Remote Monitoring und groessere Systeme, braucht aber eben die passende GX-Infrastruktur und oft Netzwerk/Internet. Home Assistant, Node-RED oder Venus auf Raspberry gehen auch, sind aber fuer viele…

EVCS in Auto mode imported 86% from grid, barely charged the car, and the screen is corrupted

Hi, I’m seeing a very frustrating issue with my Victron EV Charging Station in Auto mode and I’m trying to understand whether this is a configuration problem, a metering/reporting problem, or a charger/communication fault. Setup 3-phase setup (MultiPlus-II 48/6k5/100-50, firmware version: 2602560) EV charger in Auto mode (firmware version: v2.07) Solar production yesterday was very good, for sure that was not the problem Plenty of sun during the day, so there should have been enough excess…

SolarSense 750 -> ESPHOME -> MQTT -> Cerbo -> DBUS -> VRM

Hi, I just bought a SolarSense 750. Unfortunately, my Cerbo GX (on the roof) and the device (in the basement) are too far apart for a Bluetooth connection. I’d like to share 2 personnals projects I wrote (with Claude’s help): ESPHome SolarSense. You just need an ESP32 with Wi-Fi near the SolarSense, and all the data will be sent to an MQTT broker, for example Home Assistant. I’m using Home Assistant on my side, but it should also work with the MQTT broker running on the Cerbo. MQTT SolarSense…

Load battery at high energy costs while sufficient energy available in the battery

VRM installation ID 850738, 3 Phase installation (MultiplusII), Ecoworthy 5-pack battery (25kWh), CerboGX, Smart Solar charger 250/60 DX-DX Intention of use: Green home Solar max up until today 14kWh against consumption 7-10 kWh Expected: Use solar for home and loading battery, ad load from grid to top up battery when cheap (15 min. tarifs and max 36 hour prices known in the system). Use solar and battery when prices are high. I can’t get it working this way, even today the system started…

500 Internal Server Error Venus GX device - maybe a memory leak?

Goodmorning, When trying to connect to a Venus GX device by using a local ip-number I receive the response ‘500 Internal Server Error’ nginx/1.24.0 (doesn’t matter if I want to connect to the old or new UI). VRM is still getting ‘Real time’ information from the device except the values from the tanks. Given the fact temperature and tank values are starting the problem I have the idea something is wrong there. Connecting to the console from VRM still works. This is how I reset the site by using…

EV Charger and Heat Pump with DESS

Hello, I’m starting DESS and I would like to have a better energy management with my ev charger (on AC-IN Side) and my heat-pump (on AC-OUT). If I put an energy counter for the ev charger, can DESS take it into account ? The same for heat pump with the weather forecast? I don’t want DESS provisioning kwh for ev charger because we are using the grid power directly. I also want DESS to be more predictive with the weather forecast with my heat pump usual consumption. I think actually DESS is not…

Capacity tariff peak shaving — effekttariff (SE) / capaciteitstarief (BE)

Hi everyone, I’ve been working on a Node-RED node for managing capacity-based grid tariffs, and it’s reached a point where I’d love to get more people testing it. Just to set expectations upfront: this is a work in progress, results are not guaranteed, and you should treat it as experimental. The problem Several European countries have already or going to introduce capacity tariffs that charge you based on how high your peak consumption is, not just how much energy you use overall. If your…

Communication between VE.Bus BMS NG and Cerbo GX

Does anyone know whether the (dis-)charge current of the NG batteries is communicated by the VE.Bus NG to a GX device ? The BMS manual (section 8.2) only speaks about how to make the SOC visible on a GX device. The NG battery manual (section 5.1) shows a table which confirms that battery voltage and temperature is communicated to the GX but current apparently not. But the introduction of the VE.Bus NG on the Victron site (VE.Bus BMS NG | Victron Energy) says that it “…derives all key parameters…

Manually setting the State-of-Charge (SoC) via Node-RED

Dear Community, My system has been running flawlessly for over three years, but last December I experienced problems with the battery state of charge (SoC) and voltage. Due to the three weeks of bad weather here in Vienna, my batteries weren’t really charged. Since SoC is only a calculated value, and the Lynx shunt doesn’t seem to be very accurate at the lower end, individual cells in my 16S 560Ah battery discharged to almost 2.5V, even though the VRM still showed 27% SoC. Therefore, I changed…

MultiPlus-II constantly switching between Passthrough and Bulk

Hi Everyone! I have recently configured the ‘charge current control’ assistant using AUX1 on the MultiPlus-II connected to the NC Relay 2 on the Cerbo GX. The idea is to use the ‘Relay 2’ switch in VRM to enable/disable the charger. This all works perfectly fine, but since adding the ‘charge current control’ assistant, the MultiPlus keeps switching into ‘Bulk’ for about a second before switching back to ‘Passthrough’. This can happen multiple times a minute with gaps of up to 30 minutes and I…

BETA: Connect your Electrical Vehicle to VRM

We are currently BETA-testing a much-requested feature in VRM: Linking your electric car to VRM. In this post, I’ll explain to you what this unlocks, and how you can get started on testing. Why would I link my EV to VRM? You are probably checking both your car manufacturer’s app as well as VRM while your car is charging. Seeing the state of charge of your car in VRM saves you switching apps.VRM will offer some features that most car brand apps don’t offer, like: Being able to historically see…

Enhancing DESS Cybersecurity: A Safer Alternative to Full VRM Remote Access

Good morning, I’d like to raise a concern regarding the cybersecurity of DESS systems, specifically the risk of potential hacker attacks via the internet. If I’ve misunderstood any existing configuration options, I apologize in advance and would appreciate any clarification or guidance. To ensure robust cybersecurity, I believe DESS systems should be configured with the following principles: Critical system configurations—such as GX settings, MPII configurations, and firmware updates—should be…

VRM doesn't show energy prices

Since two days the VRM app doesn’t show me the energy prices? Yesterday and today it tells me no data to display. And only uses power from the grid instead of also from the batteries. I don’t see other people complain about this. So could be only with my installation. Does anybody have an advice how to solve this? 15 posts - 7 participants Read full topic

Time zone mismatch: Cerbo vs. VRM portal (DESS schedule 2h offset)

Hello community, I’m having an issue with the time handling between my Cerbo and the VRM portal. On my Cerbo the time zone is correctly set to Europe GMT+1. When I configure my DESS tiered electricity prices (different rates depending on time of day), they are shown in the VRM portal with a 2-hour offset. This makes the whole schedule wrong because it’s using the wrong time base. I can work around it by entering the times manually shifted, but that becomes incorrect again whenever we switch…

DESS and SG-ready with Node-RED

Hi, I was wondering if anyone here has experience using Smart Grid in combination with the two available relays on the Cerbo. My heat pump is SG-ready, and I expect the scheme from DESS to be suitable for controlling it. SG-ready is operated via two signals, which I want to switch using the Cerbo relays. See below: For switching states 2 and 3, these correspond to the purple and blue bars shown in the VRM scheme, but this isn’t a status I can directly retrieve from Node-RED. For switching state…

MP2 generates flow of low battery alerts and clears, every 30 seconds

Today my installation acts weird and created a flow of notifications that made vrm suspend my alarm notifications. This morning the battery reached 10% which I set as minimum SOC yesterday. I would expect as normal one notification alert and later in the day another cleared notification. Instead my system decided to clear every 30 seconds and create another low battery alarm notification. Weird behavior. I do not think I changed a setting, not knowingly at least. In advanced tab two graphs that…