Victron Community - Topics tagged vrm

Topics tagged vrm

Corrupted BMS-Can values on Cerbo GX traced to Ethernet duplex mismatch

Sharing this in case it saves someone a month of troubleshooting. In my case a network problem on the Cerbo’s Ethernet port showed up as corrupted battery data on the BMS-Can port. System Cerbo GX, Venus OS v3.75 → v3.80 (no difference between versions) 9 × Pylontech US5000 on the BMS-Can port (BMS firmware v1.6 as reported by the GX) MultiPlus-II 3-phase, ESS with Dynamic ESS Home Assistant reading the GX over Modbus TCP, later also over MQTT Symptom Every now and then a single sample from the…

VRM graph x axis offsets - suggestion

Hi, I noticed that values in the VRM graphs are drawn on the x-axis with an offset of half an hour. This is the case both in VRM on the web and in the VRM app. Both bars and points show this behaviour. See the example below, in this bargraph the bars are centered on the full hour. However the period for which the value is given is from 7:00 to 7:59. In this layout the bar suggests it represents an average or total taken from 6:30 to 7:30. I propose the bars are centered on the half hour, so…

Non Receipt of One-time code

How do I get assistance with non receipt of One-Time codes?. I can no longer access VRM on my phone as it accepts the password but then requests a one-time code that never comes. The phone number in my profile is correct. I would turn off 2FA but that also requires a One-time code that doesn’t come. 1 post - 1 participant Read full topic

Smart MPPT 100/20 ne produit pas

Bonjour la communauté victron, Cela fait maintenant un bon moment que je cherche à résoudre un problème par moi même et je viens finalement chercher de l’aide ici car ni mon distributeur, ni mes collègues installateur ne trouvent la solution. Je suis sur un site isolé, j’ai un multiplus 2 GX, un smart bms NG avec le distributor, une batterie lithium 24/100 NG victron ainsi que 2 smart MPPT: un 150/45 pour un champ avec 4 panneaux (2 série et en parallèle) à l’Ouest et un 100/20 avec un panneaux…

System unable to charge from generator

You may want to feed this into them too. I have just dealt with the fourth instance of generator fails to charge battery bank. Everything appears normal, generator runs, all connections are sound, fuse are closed etc. Batteries do not charge and VRM (and Smarshunt viewed locally confirms no charging is taking place). The following appears to resolve the issue: Using the manual MP rocker mode selector, select charge only. Wait until MP shows AC is charging, and MP is in bulk. Return rocker…

Accuracy of the VRM app figures?

Are the consumption figures in the VRM app known to be accurate? The Victron app shows an average of about 1.2 units a day from the grid. However, the electricity meter shows an average consumption of 3.42 a day. Big difference! 3.42 looks suspiciously close to the total consumption, that is solar plus grid. According to the electricity meter, we have used 613.31 between 19th April and today. If i check the same period on the app it says only 344 from the grid. (This is a house that’s not been…

Garmin Watch is missing Relay 1

I use a Garmin watch with the VRM widget. The Relay 1 of Cerbo GX is setup as a manual switch. It appears in the GUI of VenusOS interface as well as in VRM, but it does not appears on my Garmin Watch. I have also configured a switch from a Shelly 1 Gen4, and it appears on my watch, as well as Relay 2. 2 posts - 1 participant Read full topic

Access to vrm portal

I sent installation id a few weeks ago and nothing. got a cerbo gx used i can access acress from my network and would like remote access . i got remote console but no vrm portal . I have the app installed and cerbo is on ethernet cable. i tryed to send xlsx file but wont let me. everytime i try to send it says bad file type. i remote into my other stuff on my network no problem to turn off stuff like lights and other things . AM I MISSING SOMETHING? 10 posts - 5 participants Read full topic

EVCS hat wieder keine Verbindung mit CCGX

Hallo, Leider besteht erneut ein Verbindungsproblem zwischen meinem EVCS und dem CCGX. Die Internetverbindung beider Geräte ist intakt, jedoch wird der EVCS auf dem CCGX als „nicht verbunden" angezeigt. Zudem lässt sich am EVCS der Akkustand nicht abrufen, und über VRM gibt es keine Einstellungsmöglichkeiten für den EVCS – obwohl das Smart Solar dort zwar vollständig mit allen Daten sichtbar ist, aber keinerlei Steuermöglichkeiten bietet. Interessanterweise konnte ich gestern trotz bereits…

Virtual Indicator shows up in VRM as "Expansion IO" – can't create widgets/graphs for its values

Hi all, I’m using the new Virtual Indicator node in Node-RED on a Venus OS Large test system and I’m running into a limitation in VRM. I’m posting it here to check whether this is expected, planned, or whether I’m missing a setting. Environment Venus OS Large 3.81 node-red-contrib-victron: [version from palette manager] VRM portal (production) What I did I created four Virtual Indicator nodes (two Discrete, two Value type) in the same Group, “Calitatea aerului” (air quality), fed from a flow…

VRM App (IOS) and VRM web portal show different data (SOC)

Hello Victron team. VRM App (IOS) no longer shows any data for SOC (Battery Monitor widget) while VRM web portal still does . Why different behaviour? This happens since a couple of weeks/months only. Release bug ? See below screenshot for both VRM App and Web Portal (same time). Thanks for your answer , Christian 4 posts - 2 participants Read full topic

DESS stays "Off" on Multi RS 48/6000, balancing message never clears

DESS is enabled in VRM (trade mode, Tibber NL), but the dashboard keeps showing “Dynamic ESS – Off” with no schedule. The Multi RS shows “External control”. Firmware: Multi RS 48/6000/100: v1.31 (VictronConnect says latest) Cerbo GX MK2: Venus OS v3.81 VictronConnect: v6.43 Battery: 2x Pylontech on CAN Already tried: toggling DESS off/on, rebooting the Cerbo, updating firmware (Cerbo from v3.67, Multi RS from v1.26), BatteryLife off, Modbus TCP off. I also see “Battery balancing is scheduled…

Is it normal to have AC Out drops when the grid is lost?

Hi everyone, I have my Multiplus II 48/6k5 GX for some 2 full months now and I have fixed most issues which were mostly from my lack of knowledge of the various parameters (I installed the device myself based on the many hours of reading and watching videos). My installation has an AC Coupled Huawei inverter which holds the solar panels. There is a 16KW Dyness battery as well. Just today the grid was out for 4 hours and I am very happy with the investment so far. The PVs continued to produce…

Adjusting DESS EV consumption forecast via Node-RED – HTTP 429 and local alternative?

Hi, I’m working on a charging planner for two cars, using Node-RED on a Cerbo GX. The idea is to calculate when the cars should charge, based on electricity prices, required energy and departure times. I would like to send the expected EV consumption to DESS so it can take this into account when planning battery charging and discharging. I’m running Venus OS 3.81 with VRM-DESS and victron-vrm-api v0.4.4. I managed to get the post-adjust-consumption function working. I can add an EV consumption…

Cerbo GX Röle kapalı olmasına rağmen VRM de röle görünüyor

Merhaba arkadaşlar. Victron Cerbo GX ile webastomu çalıştırıyorum. Cerbo GX üzerinde bulunan 2 rölenin birini AÇMA tetiklemesi diğer röleyi KAPATMA tetiklemesi olarak kullandım. Node-RED üzerinden bu kontrolleri hazırladım ve Röle ekranına gösterdim. Sorunum 1. Röle için Node Red ile açma kapama bölümü eklememe rağmen Cerbo GX üzerinden röle gösterimini kapatmama rağmen VRM portalda istemediğim röle hala aktif görünüyor. VRM Portaldan bunu kapatamıyorum. Görünmesini istemediğim bölüm GX Cihazı…

VRM has lost ability to control inverter input current limit

Recently my VRM has lost the ability to control the inverter input current limit. First noticed about 10 days ago then returned to normal and now has disappeared again. It does still work normally via the local display however. I have turned Inverter Control off and back on via the VRM control panel with no success. Is this just me or more widespread? I should add I haven’t changed anything recently or updated any firmware. Working one day, gone the next! TIA 11 posts - 7 participants Read full…

Global link 520 shows its a 530 in the vrm the label had Global Link 520

Device list for KINROSS truck First seen: 2026-10-14 10:40:51 Open in VictronConnect Gateway Last seen 4 hours ago Product GlobalLink 530 Firmware version v3.00 Signal RSSI Excellent (-63 dB) Antenna type Internal Network name T-Mobile (310260) Last connection 4 hours ago Logging interval 15 minutes VRM portal ID [Moderator edit: ID removed] Last power up or restart 2026-10-14 16:44:56 (4 hours ago) Serial number HQ2525KE2GJ GlobalLink 520 Settings A few of the GlobalLink’s settings can be…

Quattro-II 48/5000 Fault / No AC Output Following Firmware Upgrade v556 to v560

Hi All, Looking for assistance with a Quattro-II 48/5000/70-2x50 (Product ID 2651) that has stopped working following a firmware upgrade from v556 to v560 through VRM. The unit was working normally before the upgrade but is now reporting Fault with no AC output. System: Fully off-grid, no AC input connected. Cerbo GX, 4 × Pylontech US5000 batteries and Victron MPPTs. Batteries and BMS operating normally, no alarms. Firmware upgrade: Upgraded from v556 to v560 through VRM. Update reported Error…

Darstellung Erzeugung und Verbrauch im VRM Portal

Hallo in die Runde wie ich meiner “Vorschau” entnehmen kann, sind diese Leistungskurven “für einen Tag” offensichtlich vorhanden. Sowohl für die Lasten als auch für den Solarertrag. ich müsste sie quasi nur in einem Diagramm “summieren” zu einer Tages-Kurve bzw. würde mir diese wegschaltbar auch einzeln anzeigen lassen. Man kann im VRM Portal hunderte Parameter in einem Diagramm zusammen führen. Doch woher holt Victron diese hier dargestellten Daten? Output Power hingegen zeigt mir den…

VRM release notes 14-10-2026

Hi all, I would love to share with you the latest changes that were just added to production VRM: Dynamic ESS: users with read-only access to an installation can now see the Dynamic ESS settings. They cannot change anything; the wizard and the on/off switch stay closed to them. The event log tells you a lot more: Installation notes now show who wrote them and the note text. More events now show who performed the action. A new entry is added when someone generates or downloads a site report.…

MultiPlus-II 4k5 + one Dyness DL5.0C Pro shuts down on grid loss with Low Battery and High DC Ripple

Hello everyone, I need help diagnosing a grid-loss issue with the following system: MultiPlus-II 4k5 1 × Dyness DL5.0C Pro, 51.2 V / 100 Ah SmartSolar MPPT 150/45 ESS installation During some scheduled grid outages in Ukraine, the MultiPlus-II goes into Off for around 10–30 seconds, causing the lights and other loads to lose power briefly. The unit then restarts and enters Inverting mode. VRM reports Low Battery and High DC Ripple, although the battery voltage remains around 52.7–53.3 V, the…

EVCS Opportunity Loads and available solar

How do the GX and EVCS decide how much power to use for EV charging? When controlled as an Opportunity Load, the EVCS is using about 500W more power than is available from solar, even when the charging current could be reduced down to the 6A minimum. I’ve just installed an EVCS, because of the ability to charge from available solar. I have a Cerbo GX (firmware v3.8)1, Multiplus and Smart Shunt, which charge the battery from solar during the day, and powers my data cabinet (Essential Loads)…

Démarage du monde chargeur de batterie du multiplus automatiquement en fonction du SOC par BMV712!

Systeme hybrid, 24 panneaux solaire de 195 watts eco-worthy Multiplus 2000 watts, chargeur 12 volt 80 ampere integré 3 MPPT victron 150/85 Cerbo-s GX et ecran touch 50 tout le systeme est relié bluetotoh , cellualire et VRM ve config JE vous tout simplement que: le victron demmare automatiquement le mode chargeur du multiplus lorsque le BMV 712 shunt et ou autre indique un soc determiné. Donc exemple a 50% le multiplus active le chargeur et a 60% de soc il arrette! J’ai tout essayer avec…

Unable to log into VRM App on iPhone

Yesterday my VRM App on my iPhone 14 lost its login for no apparent reason. In attempting to log back in on my iPhone, I enter my email, a new window opens, a progress bar advances and disappears, but the page never loads. It remains empty and the log in process does not advance. VRM on my desktop devices still works normally. I use Brave as my browser and have since I’ve had the App. The issue does not change if I turn off Brave protections for victronenergy.com, so I don’t suspect Brave being…

Configuration Cerbo GX - ESS

Hello, J’ai enfin pu mettre en service mon installation le vendredi dernier 09 Octobre, Il s’agit d’une reprise et remise au normes de l’installation de l’ancien propriétaire. Vous trouverez ci-dessous le schéma de l’installation : Je constate néanmoins, qu’une très grande partie de ma production solaire est reinjectée dans le réseau Enedis au lieu de charger les batteries. Par exemple, aujourd’hui à 11h ma production solaire relevée sur l’onduleur est de 2797 W. Dans VRM, j’ai ce qui suit : Et…

Título: Venus OS 3.81 – Limitación de la potencia de entrada de red

Hola a todos: Quisiera comunicar un posible fallo relacionado con la limitación de potencia de entrada de red en las últimas versiones de Venus OS. Mi instalación dispone de un Cerbo GX, tres MultiPlus-II 5000 conectados en paralelo monofásico y un sistema ESS. En VEConfigure tengo configurado un límite de corriente de entrada de 63 A y la opción Dynamic Current Limiter está desactivada. Desde septiembre de 2026 he observado que el sistema no importa más de aproximadamente 10 kW de la red…

Quatro/Multiplus State/Controls incorrect in VRM

My Quattro controls and state are not showing correctly in VRM. They are displayed correctly on the local control panel. I have tried disconnecting the device and rebooting the OS so it was no longer detected and deleting the device from VRM. Then reconnecting and rebooting however this didn’t resolve the issue. As can be seen in the screenshots (Wobbly & Control Panel) on the local panel everything is correct yet VRM shows the status as Off yet clearly in the background you can that it is…

Negative prices are not displayed as 0

Info message now appears in VRM saying that negative prices are displayed as 0, but I don’t see it working. Is “My prices can be negative” setting applied to spot price or the final price after applying the sell/buy formula? My sell price formula is “p - 0.02”, but it cannot go lower than 0. In other words, I get a credit of current sell price minus 2 cents, but I don’t get charged when spot price is below 2 cents or even negative. My chart still shows negative sell prices In this market…