Hi there, In VRM beta I see there’s a new “PV Arrays” configuration option. We have an AC coupled PV array with microinverters for each panel. I see the “Number of strings” is optional, but does it impact the algorithm at all? (e.g., is it better if I set this to 8, in my example below, given that each of the panels are independent) Does anyone have any insights on the feature? I’m excited to see how this affects the yield estimates. 1 post - 1 participant Read full topic
V
Today dess decided to power the house from battery while using grid is cheaper. Why is this happening? 12 posts - 4 participants Read full topic
V
VRM portal c0619ab4b607 Kan iemand de ghost EVCS verwijderen uit de backend s.v.p.? Staat niet in apparatenlijst Staat niet in VRM-devices (settings) Reboot helpt niet Vorige VenusOS boot helpt niet Bij voorbaat hartelijk dank 1 post - 1 participant Read full topic
V
Hallo, Ich habe seit kurzem meine neue PV Anlage in Betrieb (3x RS Smart Solar, Cerbo + Batterie) und würde gerne jetzt auch DESS nutzen. Ich hab im VRM Portal DESS konfiguriert (obwohl es leider nicht möglich war Octopus Energy als Stromanbieter auszuwählen) und dort steht jetzt DESS auf an. Jedoch wird im Dashboard DESS als“Aus“ angezeigt und DESS funktioniert auch nicht. Kann mir jemand helfen was ich da anders einstellen muss, dass DESS funktioniert? Screenshots anbei. Ich bin über jede…
V
Hope to get some help from Victron Staff I have unexpectedly lost access to VRM installation 1024908. I originally registered and configured this installation and was its only administrator. I created a separate read-only account for my customer. The installation was previously part of my installation group 8721. It has now completely disappeared from my installation overview and group. When opening the installation URL directly, VRM reports that I am not authorized to access it. It is possible…
V
I have a system with a Multiplus 4k5 GX on L1 with an Omnik PV inverter on AC Out and an Enphase PV inverter on L2. Also they are correctly configured, the omnik on AC Out and the Enphase on AC In. But unfortunately in VRM only 1 PV is show on AC Out and in the Victron Console only 1 PV inverter is show on AC In. In the device details in the settings of the Victron console everything is on the right phase. How can I make the inverters show on the right side of the Victron showing the right…
V
Hi, Today my system is in a grid loss event thus the victron system goes in emergency mode. All loads are properly serviced from the battery and pv is stored in the battery. So far so good. However, I also have a schedule at 22:02 to load the battery to 50% in 5:50 hours. Still with a SOC of 69% and coming at around 22:00 the system hard shuts down without error or anything in the logs or VRM. All three multiplusses are off. Since the SOC is way above the threshold of 50% no charging should…
V
Hello I got a problem with the installation of node-red modules. When I try to install a new module in node-red, it takes to long to install and after 2 minutes the connection with the VRM is lost, the cerbo is blocking and after 4-5 minutes the cerbo is rebooting. I update already all the software to the last version, without any success. I tried already to install node-red modules via the local way, so without VRM, this gives me the same problems. Any suggestions how I can solve this problem?…
V
I found a recent thread about the Shelly Pill: https://community.victronenergy.com/t/how-to-use-data-from-shelly-pill-with-attached-temperature-sensor-in-vrm-dashboard/63241 But It wasn’t clear if the Pill can easily be used with its Wifi connection to VenusOS. The Pill is a tiny and affordable way to get temperature values into Venus. I wasn’t sure if I could use it connected via WiFi to control diversion loads or integrate into Opportunity Loads (OL) in Node Red. However it does work, and I…
V
hallo, heute musste ich mich einmal intensiver mit einem meiner 3-phasen-system mit mp2 befassen, weil es sich sehr merkwuerdig verhalten hat! also habe ich zuerst einmal die config ueber das vrm heruntergeladen und dabei folgendes festgestellt: mp2 1 mp2 2 mp2 3 ups an an an aes aus an an erdungsr. aus an an ich habe danach erst einmal die ups-funktion deaktiviert und an alle gesendet (ueber veconfig und mk2) und ueber das vrm kontrolliert, keine aenderung! jetzt habe ich ueber den mk2 den…
V
I have some issues with Shelly 1 Gen 4 devices that just disappear from the VRM and Cerbo. They are being used as 12v smart switches. Latest version have done it over multiple versions 20260923-075739/2.0.1-ge1a198b Cerbo 3.85 but has similar issues going back to 3.70 which were supported to have been fixed. All devices have static IP address and reserved in router, eco mode is off, they respond from the Shelly app and work as expected but just disappear from anything victron. Any suggestions,…
V
Hi, I’ve successfully connected a bilge pump and high level flow switch (via an opto isolator) to my Cerbo. I’m able to set them up as devices and see their state on the Cerbo’s display. What I’d like to be able to do it track the pump’s daily run times, and number of cycles plus send an alert if the pump has run continuously for more that a configurable time period. I’ve built (with a bit of AI help) a NodeRed flow that exposes that data to SignalK quite successfully. I’ve also posted it back…
V
Hi everyone, I need some advice with a second-hand Cerbo GX. I bought through a WhatsApp group. The unit is still registered to the previous owner’s VRM account. I don’t know the original owner because the system was removed from a house during renovations. The seller is no longer responding. I contacted Victron Support (VSID 69013), and they referred me to a dealer based on the serial number. I contacted the dealer on WhatsApp, but they said they couldn’t find the unit in their database. They…
V
Mijn ip22 lader is niet meer zichtbaar in mijn VRM portaal nadat de 230 spanning eraf is geweest. Ik lees het systeem uit met een globallink520, daar is bij Bluetooth de lader wel zichtbaar. Tik ik op de lader dan is hij wel weer zichtbaar in VRM. Het kan toch niet de bedoeling zijn dat dit iedere keer via Victron connect moet gebeuren, de andere apparaten die via Bluetooth verbinding hebben zijn wel zichtbaar in VRM. Iemand een idee wat hier fout gaat 12 posts - 4 participants Read full topic
V
Ben ik de enige met dit (mogelijk tijdelijke) probleem? Er mist een heel stuk data maar het lijkt erop dat dit tijdelijk is want de gegevens van een uur eerder lijken wel telkens aangevuld te worden. Had ik door de wintertijd nog ergens een tijd moeten aanpassen in venus of de multi solar rs? 3 posts - 1 participant Read full topic
V
Hi Victron team, The VRM dashboard tile for a Meteo device currently only shows Irradiance (W/m²). On my boat there is no irradiance sensor, but I do have wind data. I publish it as a Meteo device using the Node-RED virtual device (node-red-contrib-victron), with the /WindSpeed path in m/s. What works: - The GX device shows “Wind speed 4.2 m/s” under Settings > Devices > Wind. - The value is available in VRM Advanced, where I can graph it. What doesn’t: - On the VRM dashboard the tile only…
V
I have a single Multi RS Solar with a BMS NG and both MPPTs used. For the winter I switched DESS off (in VRM and in GX) and use ESS. I have set a Schedule Charging Schedule from 11h to 15h to 80% I set the AC current to max 6A. The system charges with 6A, fine. If there is solar, it charges more, fine. Reaching 80%, it stops charging from grid, fine. After that point, it feeds all PV to the grid. Not fine. Per the docs, it should charge. When the feed-in exceeds 6A, it starts charging with what…
V
Hallo, Ik ben nieuw hier. Ik heb een installatie met 3x een multiplus ii 5000VA en 32 kWh aan batterij capaciteit. Ik heb de set bij Helion Energie gekocht. Mijn systeem draait sinds 4 oktober goed. Ik heb daarvoor problemen gehad met een slechte cerbo en daarna een slechte datakabel. Beide problemen zijn nu opgelost. Ik heb een dynamisch energiecontract met kwartierprijzen en DESS staat op handelen. Wat me opvalt is dat de beslissingen van DESS soms totaal niet logisch zijn. Vandaag en morgen…
V
Is the Shelly 3EM-63W and Shelly 3EM-63T supported? 9 posts - 4 participants Read full topic
V
The Admin users of an installations appear not to be able to view a recurring report created by another user (in this case a technician user). Is this by design. Would it be possible to ensure Admin / Technician users have full system oversight, including recurring reports that have been created by others. 2 posts - 2 participants Read full topic
V
The Hybrid Genset reports currently only appear to allow for the setting of a fuel type of ‘Diesel’. Is this by design? If so, would it be possible to allow for the setting of other generator fuel types (maybe a drop-down selector) such as Petrol & LPG. 1 post - 1 participant Read full topic
V
In the VRM it appears there is no way for a user to ‘edit’ a reporting template they have created. Given the constantly changing price of generator fuel, would it be possible to allow a user to edit the fuel cost used in calculating a report. It appears currently a user must create a new report & delete the old report to simply amend the price used for fuel cost calculations. I appreciate this would require some logic to allow for pro-rata calculation of the final reporting costs, based on the…
V
Guten Morgen liebe community Ich habe eine Frage wegen dem einloggen in das VRM Portal. Ich habe das Problem, dass wenn ich mich einlogge, dann klicke ich an eingeloggt bleiben oder an mich denken aber jedes Mal, wenn ich die Seite wieder neu aufrufe, muss ich mich wieder neu anmelden und es ist egal, ob ich das im Safaribrowser mache auf dem Mac oder auf dem iPhone oder iPad jedes Mal muss ich mich neu anmelden obwohl, dass ich das anklicke. Hat dieses Problem eventuell noch jemand und weiß…
V
Habe heute um 7.45 Uhr den Kontakt zu meiner Anlage verloren. Eine Ferndiagnose über VRM war nicht möglich. Erstmal durchatmen … eventuell ja nichts schlimmes. Dann später mal zu Hause vorbeigeschaut … Erste Diagnose war eine ausgelöste Flachsicherung im 48V Bereich (Primärseite) welche einen (wertigen ) 48V zu 5V Wandler versorgt(e). Die 5V versorgen (eigentlich) 2 USB Hubs, eine Netzwerkbrücke für die Auslesung der Pylontech und einen Switch. Jetzt keine Spannung …also keine Kommunikation…
V
Good morning, I am having trouble with proper SOC readings in a new installation with an Easysolar II GX in combination with lead acid batteries and no external battery monitor or shunt. It is our first installation with an Easysolar (all other are Multi or Quattro with external MPPT and Cerbo GX) and the only installation using victron components with lead acid batteries (all other are either not Victron or use lithium batteries with external BMS). So this is somewhat new to me. I tried to…
V
Somehow my Growatt PV inverters have gone missing after the grid connection was upgraded from a single phase to 3-phase connection. Both missing in VRM and in VenusOS. I’m actually a bit puzzled about this since two of the AC connected inverters are still on L1. Still charging the battery, and the production is still visible on a self made NodeRED dashboard. Currently still only one Multiplus II on L1 (bidirectionally connected on AC-in) and the battery is charging, but not using all PV power.…
V
Hi, Currently, only alarms can be ‘pushed’ from nodeRED as a notification to someone’s phone. However it would be extremely useful for me as system installer/programmer to also send INFO notifications via the app. e.g. when the SoC reaches a certain minimum, a temperature a certain level, EV charger starts or any other significant event. Hence, a request to add INFO class notifications that can be triggered in nodeRED. 1 post - 1 participant Read full topic
V
Hi I have noticed a strange behavior on VRM recently on one of my sites. This is a purely single-phase, on-grid installation, with loads on both the input and output of the inverter (MultiPlus-II 10000), a Victron MPPT and a Solis PV inverter on AC-Out 2 monitored by an energy meter. This all displays correctly on VRM, and used to do so always. Recently however I have noticed that sometimes at random - I haven’t been able to pick up a trend as to what triggers this - VRM will spontaneously…
V
Hi all, I would love to share with you the latest changes that were just added to production VRM, most of them on the dashboard: On the dashboard, temperature cards for Ruuvi sensors now show an extra “Air quality” row, with a score and a label that tells you at a glance what that score means. The minigraphs (the graph in the dashboard cards) and Dynamic ESS graphs on the dashboard now refresh automatically. So if you keep VRM open on a screen all day, or your laptop or tablet wakes up from…
V
Victron Wallbox lädt nicht im Auto Modus "Warte auf Sonne" - ERROR The statistics on VRM and the remote console overview are also better if the system knows the PV power. I have 4 PV inverters AC coupled on ACin that I’d like to include in the CerboGX ecosystem. For several years these inverters are being measured by a single c.t. connected to an OEM emonCMS logger. The emonCMS publishes the total wattage using its MQTT broker on the same LAN as the Cerbo. I’ve been unable to find any…